How to Guide

A Division of Reliance Worldwide Corporation
2400 7th Avenue S.W · Cullman · Alabama 35055 · USA · www.cashacme.com
US Contact: 1-877-700-4242 · sales@cashacme.com · Canadian Contact: 1-888-820-0120 · canadasales@rwc.com
Specifications & Sales Sheet • Issue Date March 2014 • Last Revision March 2017
Heatguard
®
110-D
with Direct SharkBite Connections
DESCRIPTION
The
Heatguard
®
110-D
is a Temperature Actuated Mixing Valve that mixes hot water with cold to
deliver tempered water at a controlled temperature to 120°F (49°C) maximum. The
Heatguard
®
110-D
is designed to assist in the prevention of scalding.
The
Heatguard
®
110-D
is intended for installation at the water heater to distribute controlled
temperature water through the domestic hot water system or at point-of-use applications. The
valve delivers water at a maximum of 12F (49°C), allowing the heater to be set at 140°F (60°C)
or higher, thus providing a greater effective volume of hot water and reducing the chances of
Legionella bacteria growth in the water.
The
Heatguard
®
110-D
is a high quality mixing valve incorporating the latest in Thermostatic
Technology. It features a robust design based on the expertise gained from years of experience
in the design and manufacture of safety valves. Every valve is tested for performance on an
automated testing station during the assembly process. The valve is third party listed for both
distribution and point-of-use applications.
The
Heatguard
®
110-D
incorporates a fast acting, high quality thermostatic element that senses
the outlet water temperature and reacts to maintain a stable delivery temperature even under
changing flows or variations in supply temperatures. The valve also greatly reduces the outlet flow
in the event of a cold water supply failure.
The
Heatguard
®
110-D
features a locking mechanism to prevent unwanted adjustment above
120°F (4C).
All valves are supplied standard with check valves.
FEATURES AND BENEFITS
Certified for distribution and point-of-use applications.
Safer hot water from all outlets.
Allows the water heater to be set at 140°F (60°C) or higher
:
Greater effective hot water volume yields less chance of
Legionella within the cylinder.
Every valve is tested for performance prior to shipping:
Specify and install with confidence!
Robust, low complexity construction:
Superior reliability, improved user safety.
Adjustable and lockable mechanism:
Minimizes unauthorized tampering with valve setting Factory set, locked to maximum 120°F (49°C)
Listed by IAPMO and ASSE:
Inspector friendly, peace of mind!
SPECIFICATION
A Temperature Actuated Mixing Valve shall be installed at single point-of-use fixture or at the water heater to distribute
tempered water throughout the domestic hot water system at a maximum temperature of 120°F (49°C). The valve shall be
certified to ASSE 1017, ASSE 1069, ASSE 1070 and CSA B 125.3 standards and shall be listed by a third party. The
Temperature Actuated Mixing Valve shall control the delivered water temperature via a regulating piston made from
engineered polymer. The adjusting mechanism shall be protected by a lockable cover. The valve shall be a Cash Acme
Heatguard
®
110-D LF
.
TRIPLE LISTED!
ASSE 1017
ASSE 1069
ASSE 1070
24548