How to Guide

INSTALLATION INSTRUCTIONS
I0460 Rev. B
Cash Acme
A division of the Reliance Worldwide Corporation
2400 7
th
Avenue SW • Cullman, Alabama
Tel: (256) 775-8200 • Fax: (256) 775-8238 • Toll Free: (877) 700-4242 • www.cashacme.com
Once the shut-down has occurred this product will reduce the
flow of hot water to a trickle. This continuation of water flow is
necessary to allow resetting to occur.
It is recommended that this product be tested monthly.
RESET:
When ShowerSafe
shuts down the hot water flow, turn off the
hot tap, stand clear of the flow and open the cold tap.
ShowerSafe
will reset as soon as the hot water is purged from
the pipes.
Turn on the cold water to achieve the desired flow rate, then
introduce hot water until the preferred temperature is reached.
VALVE SPECIFICATIONS:
Hot water supply temperature 185°F max
Water supply pressure static 200 psi max.
Flow rate @ 73 psi:
Normal greater than 6gpm
Shut-down less than 0.1gpm
Nominal Set temperature 120°F (+/- 3°F)
Max. Operating Pressure 145 psi
Min. Operating Pressure less than 1 psi
WARNING
This product is designed to reduce the incidence of scalding;
however hot water will trickle from the unit when shut-down
occurs.
Shower fittings fitted with this product should not be operated
by children without parental supervision.
This product may not operate properly if incorrectly installed.
It is recommended that this product be replaced if test failure
occurs.
This product is not a substitute for Tempering Valves or
Thermostatic Mixing Vales.
FUNCTION:
Storage hot water systems should deliver water at a
minimum of 140°F to prevent bacteria growth. However at
this temperature it takes one second for a severe burn or
scald to occur!
ShowerSafe
is designed to ensure water is delivered at a
temperature of not more than 120°F. Providing it is
correctly installed and operated, the bath water
temperature cannot exceed this temperature, thereby
protecting individuals from hot water burns. Its quick shut-
down action also assists in prevention of scalding should
the hot tap be accidentally turned on.
OPERATION:
For normal operation, first turn on the cold water to
achieve the desired flow rate, then introduce hot water
until the preferred temperature is reached.
TEST:
When testing, ensure that no person is in the line of
flow of water or in the catchments of the water.
Have a strong flow of warm water pass through the
shower fitting, then close the cold tap & observe the
water shut-down.
Thread Size ½” NPT
Direction of flow
ShowerSafe
Hot Water Shut-Down Valve Model: SSD
INSTALLATION INSTRUCTIONS:
YOU WILL NEED PLUMBERS THREAD TAPE
1
Ensure that the hot &
cold taps are turned
off. Remove the
Shower Head from the
Shower Arm by turning
the nut counter
clockwise.
3
2
Apply the plumbers
thread tape to Shower
Arm threads & screw
your ShowerSafe
onto the pipe as
shown.
Ensure that O-Ring
seal is fitted to your
ShowerSafe
and
screw the Shower
Head onto the
ShowerSafe
and
tighten nut with a
wrench.
Proposition 65 Warning (for California Residents Only)
This product contains a chemical known to the State of California to cause
cancer, birth defects or other reproductive harm.
NOTE TO INSTALLER/CONTRACTOR: California law requires this notice to be
provided to the consumer/end user of this product.

Summary of content (1 pages)