Specifications

45
2.2.5. Scan Result Notification
When scanning a bar code is completed, a notification about the scanning result can be indicated
to the user with either LED or buzzer or vibration. Each indication method can be set to “Enable”
or “Disable”.
Table. 2.42
Indication
method
Setting
When
succeeded
When failed
(see note 1)
Scanning
interrupted
(Trigger key
released)
OBR buffer
full
(see note 2)
Default
Mode 1 ON in green None None ON in green
Mode 2 ON in green ON in red None ON in green
LED
Mode 3
(disable)
None None None None
Mode 1
Enable Scan
completion
sound
None None Warning sound Buzzer
Disable None None None None
Enable
Enable Vibrates None None None Vibrator
Disable None None None None
Disable
Notes:
1. Scanning will fail when one of the errors occurs.
- A bar code with the number of digits which exceeds over the specified range is scanned.
- Check digit calculation error occurs.
- Full ASCII conversion error occurs in scanning bar code of Code39 symbology or Code128
symbology.
2. During the “OBR buffer output” method has been set as scanned data output method, this
condition occurs if scanning takes place while nine labels worth of data are stored already in
the memory buffer.