User Manual
Table Of Contents
- Contents
- Getting Acquainted — Read This First!
- Chapter 1 Basic Operation
- Chapter 2 Manual Calculations
- 1. Basic Calculations
- 2. Special Functions
- 3. Specifying the Angle Unit and Display Format
- 4. Function Calculations
- 5. Numerical Calculations
- 6. Complex Number Calculations
- 7. Binary, Octal, Decimal, and Hexadecimal Calculations with Integers
- 8. Matrix Calculations
- 9. Vector Calculations
- 10. Metric Conversion Calculations
- Chapter 3 List Function
- Chapter 4 Equation Calculations
- Chapter 5 Graphing
- 1. Sample Graphs
- 2. Controlling What Appears on a Graph Screen
- 3. Drawing a Graph
- 4. Storing a Graph in Picture Memory
- 5. Drawing Two Graphs on the Same Screen
- 6. Manual Graphing
- 7. Using Tables
- 8. Dynamic Graphing
- 9. Graphing a Recursion Formula
- 10. Graphing a Conic Section
- 11. Changing the Appearance of a Graph
- 12. Function Analysis
- Chapter 6 Statistical Graphs and Calculations
- 1. Before Performing Statistical Calculations
- 2. Calculating and Graphing Single-Variable Statistical Data
- 3. Calculating and Graphing Paired-Variable Statistical Data
- 4. Performing Statistical Calculations
- 5. Tests
- 6. Confidence Interval
- 7. Distribution
- 8. Input and Output Terms of Tests, Confidence Interval, and Distribution
- 9. Statistic Formula
- Chapter 7 Financial Calculation (TVM)
- Chapter 8 Programming
- Chapter 9 Spreadsheet
- Chapter 10 eActivity
- Chapter 11 Memory Manager
- Chapter 12 System Manager
- Chapter 13 Data Communication
- Chapter 14 PYTHON (fx-9860GIII, fx-9750GIII only)
- Chapter 15 Distribution (fx-9860GIII, fx-9750GIII only)
- Appendix
- Examination Modes (fx-9860GIII, fx-9750GIII only)
- E-CON3 Application (English) (fx-9860GIII, fx-9750GIII)
- 1 E-CON3 Overview
- 2 Using the Setup Wizard
- 3 Using Advanced Setup
- 4 Using a Custom Probe
- 5 Using the MULTIMETER Mode
- 6 Using Setup Memory
- 7 Using Program Converter
- 8 Starting a Sampling Operation
- 9 Using Sample Data Memory
- 10 Using the Graph Analysis Tools to Graph Data
- 11 Graph Analysis Tool Graph Screen Operations
- 12 Calling E-CON3 Functions from an eActivity
2-1
Chapter 2 Manual Calculations
1. Basic Calculations
k Arithmetic Calculations
• Enter arithmetic calculations as they are written, from left to right.
• Use the - key to input the minus sign before a negative value.
• Calculations are performed internally with a 15-digit mantissa. The result is rounded to a 10-
digit mantissa before it is displayed.
• For mixed arithmetic calculations, multiplication and division are given priority over addition
and subtraction.
Example Operation
56 × (–12) ÷ (–2.5) = 268.8
56 *-12 /-2.5 w
(2 + 3) × 10
2
= 500
(2 +3 )*1
52 w
2 + 3 × (4 + 5) = 29
2 +3 *(4 +5 w*
1
4
×
5
6
= 0.3
6 /(4 *5 )w
*
1
Final closed parentheses (immediately before operation of the w key) may be omitted, no
matter how many are required.
k Number of Decimal Places, Number of Significant Digits, Normal
Display Range
[SET UP]
-
[Display]
-
[Fix]
/
[Sci]
/
[Norm]
• Even after you specify the number of decimal places or the number of significant digits,
internal calculations are still performed using a 15-digit mantissa, and displayed values are
stored with a 10-digit mantissa. Use Rnd of the Numeric Calculation Menu (NUM) (page
2-13) to round the displayed value off to the number of decimal place and significant digit
settings.
• Number of decimal place (Fix) and significant digit (Sci) settings normally remain in effect
until you change them or until you change the normal display range (Norm) setting.
Example 1 100 ÷ 6 = 16.66666666...
Condition Operation Display
100 /6 w
16.66666667
4 decimal places
!m(SET UP) ff
1(Fix) ewJw
16.6667
5 significant digits
!m(SET UP) ff
2(Sci) fwJw
1.6667
E
+01
Cancels specification
!m(SET UP) ff
3(Norm) Jw
16.66666667
*
1
Displayed values are rounded off to the place you specify.
*
1
*
1
2