User Manual
Table Of Contents
- Contents
- Getting Acquainted — Read This First!
- Chapter 1 Basic Operation
- Chapter 2 Manual Calculations
- 1. Basic Calculations
- 2. Special Functions
- 3. Specifying the Angle Unit and Display Format
- 4. Function Calculations
- 5. Numerical Calculations
- 6. Complex Number Calculations
- 7. Binary, Octal, Decimal, and Hexadecimal Calculations with Integers
- 8. Matrix Calculations
- 9. Vector Calculations
- 10. Metric Conversion Calculations
- Chapter 3 List Function
- Chapter 4 Equation Calculations
- Chapter 5 Graphing
- 1. Sample Graphs
- 2. Controlling What Appears on a Graph Screen
- 3. Drawing a Graph
- 4. Saving and Recalling Graph Screen Contents
- 5. Drawing Two Graphs on the Same Screen
- 6. Manual Graphing
- 7. Using Tables
- 8. Modifying a Graph
- 9. Dynamic Graphing
- 10. Graphing a Recursion Formula
- 11. Graphing a Conic Section
- 12. Drawing Dots, Lines, and Text on the Graph Screen (Sketch)
- 13. Function Analysis
- Chapter 6 Statistical Graphs and Calculations
- 1. Before Performing Statistical Calculations
- 2. Calculating and Graphing Single-Variable Statistical Data
- 3. Calculating and Graphing Paired-Variable Statistical Data (Curve Fitting)
- 4. Performing Statistical Calculations
- 5. Tests
- 6. Confidence Interval
- 7. Distribution
- 8. Input and Output Terms of Tests, Confidence Interval, and Distribution
- 9. Statistic Formula
- Chapter 7 Financial Calculation
- Chapter 8 Programming
- Chapter 9 Spreadsheet
- Chapter 10 eActivity
- Chapter 11 Memory Manager
- Chapter 12 System Manager
- Chapter 13 Data Communication
- Chapter 14 Geometry
- Chapter 15 Picture Plot
- Chapter 16 3D Graph Function
- Chapter 17 Python (fx-CG50, fx-CG50 AU only)
- Chapter 18 Distribution (fx-CG50, fx-CG50 AU only)
- Appendix
- Examination Modes
- E-CON4 Application (English)
- 1. E-CON4 Mode Overview
- 2. Sampling Screen
- 3. Auto Sensor Detection (CLAB Only)
- 4. Selecting a Sensor
- 5. Configuring the Sampling Setup
- 6. Performing Auto Sensor Calibration and Zero Adjustment
- 7. Using a Custom Probe
- 8. Using Setup Memory
- 9. Starting a Sampling Operation
- 10. Using Sample Data Memory
- 11. Using the Graph Analysis Tools to Graph Data
- 12. Graph Analysis Tool Graph Screen Operations
- 13. Calling E-CON4 Functions from an eActivity
ε-24
Using a Custom Probe
7. After configuring the required settings, press 6(SAVE) or w.
• This displays the dialog box shown below.
8. Input the custom probe registration number (1 to 99) and then press w.
• This registers the custom probe and returns to the custom probe list screen.
k Assigning a Custom Probe to a Channel
1. On the sampling screen, use f and c to select the channel to which you want to
assign the custom probe.
2. Press 1(SENSOR) to display the sensor selection screen.
3. Press 4(CUSTOM).
• This displays the custom probe list screen.
4. Use f and c to select the custom probe you want to assign and then press w.
k Changing the Settings of a Custom Probe
1. On the custom probe list screen, use f and c to select the custom probe whose
settings you want to change.
2. Press 2(EDIT).
• This displays a custom probe setup screen.
3. Perform steps 3 through 6 under “Registering a Custom Probe”.
4. After configuring the required settings, press 6(SAVE) or w.
• This returns to the custom probe list screen.
k Recalling CMA or Vernier Sensor Settings to Register a Custom Probe
1. On the custom probe list screen, press 4(CMA) or 5(VERNIER).
• This displays a sensor list.
2. Use the f and c cursor keys to move the highlighting to the sensor whose settings you
want to use as the basis of the custom probe and then press w.
• The name of the selected sensor and its setting information are shown on the custom
probe setup screen.
3. Perform steps 3 through 8 under “Registering a Custom Probe”. However, you will not be
able to change the sensor type.