user manual
Chapter 12: Program Application  211Chapter 12: Program Application  211
RclVWin  Misc - Graph&Table(2)
Syntax: RclVWin{<variable name> ; <folder name\
file name>}
Function: Recalls View Window values, which were 
previously saved under the specified name.
Description: A folder path can be specified only up to 
one level.
Receive38k  I/O - Communication
Syntax: Receive38k<variable name> 
Function: Receives EA-200 data. 
Description:
• The OpenComPort38k command must be executed 
before this command is executed.
• The CloseComPort38k command must be 
executed after this command is executed.
• For details about using this command, see the user 
documentation that comes with the EA-200.
• Note that you need to replace all instances of the 
Receive command in the examples provided in 
the EA-200 user documentation with the command 
Receive38k. You should also adjust the other 
commands in the EA-200 examples so they conform 
to the ClassPad command syntax and usage as 
described in this manual.
Rename  Misc - Variable
Syntax: Rename<current variable name>, <new 
variable name>
Function: Renames a variable.
Return  Ctrl - Control
Syntax: Return{<variable>}
Function 1 (Main Program): Terminates program 
execution.
Function 2 (Subroutine Program): Returns from a 
subroutine.
Tip
• The Return command can be executed during an If, For, 
Do, While, or Switch process.
•  Appending a <variable> to the Return command in 
the Main application and executing the command will 
cause the variable to be displayed when the program is 
complete.
S
Scatter  Misc - Statistics(1) - Graph
Function: Used as a StatGraph command argument 
to specify an option. See StatGraph.
Send38k  I/O - Communication
Syntax: Send38k<variable name> 
Function: Sends EA-200 data. 
Description:
• The OpenComPort38k command must be executed 
before this command is executed.
• The CloseComPort38k command must be 
executed after this command is executed.
• For details about using this command, see the user 
documentation that comes with the EA-200.
• Note that you need to replace all instances of the 
Send command in the examples provided in the 
EA-200 user documentation with the command 
Send38k. You should also adjust the other 
commands in the EA-200 examples so they conform 
to the ClassPad command syntax and usage as 
described in this manual.
• <variable name> must be a variable that contains 
a real number or a list. Anything else results in an 
error.
SendVar38k  I/O - Communication
Syntax: SendVar38k<variable name>
Function: Sends variable names and variable 
contents.
Description:
• The OpenComPort38k command must be executed 
before this command is executed.
• The CloseComPort38k command must be 
executed after this command is executed.
SeqSelOff  Misc - Sequence
Syntax: SeqSelOff{
a
n
+1
 ; a
n
+2
 ; b
n
+1
 ; b
n
+2
 ; c
n
+1
 ; c
n
+2
 ; 
a
n
E ; b
n
E ; c
n
E}
Function: Deselects the specified sequence 
expression. Specifying “
a
n
E”, “b
n
E”, or “c
n
E” as the 
argument activates [Explicit]. Specifying any other 
argument activates [Recursive].
SeqSelOn  Misc - Sequence
Syntax: SeqSelOn{
a
n
+1
 ; a
n
+2
 ; b
n
+1
 ; b
n
+2
 ; c
n
+1
 ; c
n
+2
 ; 
a
n
E ; b
n
E ; c
n
E}
Function: Selects the specified sequence expression. 
Specifying “
a
n
E”, “b
n
E”, or “c
n
E” as the argument 
activates [Explicit]. Specifying any other argument 
activates [Recursive].
SeqType  Misc - Sequence
Syntax: SeqType{"
n" ; "a
n
+1
a
0
" ; "a
n
+1
a
1
" ; "a
n
+2
a
0
" ; 
"a
n
+2
a
1
"}
Function: Specifies the recursion type.
Description: Specifying “
n” as the argument activates 
[Explicit]. Specifying any other argument activates 
[Recursive].










