User Manual
2385-2
Newest data Cleared from memory
Memory 1 Memory 10Memory 2
The measured data can be recalled and manually deleted in the Data Recall Mode.
To use the Depth Measurement Mode
1. Before skin diving/snorkeling, switch to the Depth
Measurement Mode by holding down C for at least two
seconds.
2. After skin diving/snorkeling, switch back to the
Timekeeping Mode by holding down C for at least two
seconds. At this time, the log data is stored in memory.
Present depth
1 minute 50 seconds submerged time
Switches to Depth Measurement Mode Switches to Timekeeping Mode
Depth = 1.0 m
(4 ft.)
Measurement
start
Maximum depth
20 sec. 1 min.
30 sec.
Notes
• Once set to the Depth Measurement Mode, the depth measurement function will
automatically make submerged time and depth calculations.
• While you are submerged, the watch will not revert to the Timekeeping Mode even if
you hold down C. This protects against accidentally changing from the Depth
Measurement Mode to the Timekeeping Mode while submerged.
• If you do not press any button on the surface (depth of “0”) for one hour, the watch
automatically returns to the Timekeeping Mode.
• Whenever the submerged time reaches six hours, the watch automatically switches
to the Timekeeping Mode.
DATA RECALL MODE
Use the Data Recall Mode to recall and delete the log
data from memory. Whenever you enter the Data Recall
Mode from another mode, the newest data is displayed
first.
• Note that the log data stored in memory is cleared when
batteries are replaced. If you wish to keep the data, be
sure to copy it into a log book before having batteries
replaced.
• If you do not press any button for one hour in the Data
Recall Mode, the display returns to the Timekeeping
Mode automatically.
Mode indicator
[ Memory Number Display ]
Memory number
To recall data from memory
1. In the Data Recall Mode, press B to scroll through the displays for memory
numbers 1 through 10.
2. While any one of the memory set displays is shown, press D to scroll through the
data contained in that set in the following sequence.
• Data accompanied by a warning mark (!) is possibly invalid.
Memory
Number
Maximum
Depth
Submerged
Time
To delete data from memory
1. In the Data Recall Mode, display the memory number display for the set of data you
want to delete.
Important!
The delete operation erases the entire set of data you have selected. You cannot
delete parts of a set of data.
2. Holding down A until the memory number starts to flash.
3. To clear all of the data in the currently displayed set, holding down C and D
simultaneously until the display shows “CLEAR”.
STOPWATCH MODE
The Stopwatch Mode lets you measure elapsed time,
split times, and two finishes. The range of the stopwatch
is 23 hours, 59 minutes, 59.99 seconds.
To change the measured time format
In the Stopwatch Mode, press A to change the
measure time display format between minutes
(00'00"00) and hours (0:00 00).
Mode indicator
Minutes
Seconds
1/100 second
Press A.
Hours
Minutes
Seconds
To measure elapsed time
1. Press D to start the stopwatch.
2. Press D to stop the stopwatch.
• You can resume the measurement operation by pressing D again.
3. Press B to clear the stopwatch to all zeros.
To record split times
1. Press D to start the stopwatch.
2. Press B to display the timing up to that point. Stopwatch timing continues
internally.
3. Press B to clear the split time and to continue time measurement on the display.
• You can repeat steps 2 and 3 as many times as you want.
4. Press D to stop the time measurement.
5. Press B to clear the stopwatch to all zeros.
To time first and second place finishes
1. Press D to start the stopwatch.
2. Press B when the first finisher crossed the line, and record the time.
3. Press D when the second finisher cross the line.
4. Press B to display the finishing time of the second finisher.
5. Press B again to clear the stopwatch to all zeros.
ALARM MODE
When the Daily Alarm is switched on, the alarm sounds
for 20 seconds at the preset time each day. Press any
button to stop the alarm after it starts to sound.
When the Hourly Time Signal is switched on, the watch
beeps every hour on the hour.
Note that the Daily Alarm and the Hourly Time Signal
operate based on the digital time setting.
To set the alarm time and switch the Hourly Time Signal on and off
1. Hold down A while in the Alarm Mode until the hours digits start to flash on the
display. The hours digits flash because they are
selected
. At this time the Daily
Alarm is switched on automatically.
Mode indicator
Hour
Minutes
2. Press C to change the selection in the following sequence.
Hour Hourly Time Signal SettingMinutes
3. Press D to increase the selected hour or minutes digits or B to decrease them.
Holding down either button changes the selection at high speed.
• The format (12-hour and 24-hour) of the alarm time matches the format you select
for normal timekeeping.
• When setting the alarm time using the 12-hour format, take care to set the time
correctly as morning (am) or afternoon (pm).
4. While the Hourly Time Signal setting is selected, press B or D to switch the
hourly time signal on and off.
5. After you set the alarm time, press A to return to the Alarm Mode.
On Off
To switch the Daily Alarm on and off
While in the Alarm Mode, press D to switch the Daily Alarm on and off.
About the alarm
There are two different alarm sounds to choose from: high and low.
To test the alarm
Hold down B while in the Alarm Mode to sound the alarm. Each time you test the
alarm (by holding down B) a different alarm sounds. The sound produced the last
time you test the alarm is the one used for the alarm.
On Off