Specifications

— 17 —
5. D-PCB Assy
5-1. VCO free run frequency adjustment
Room temperature should be 20 ± 10 °C
1. Preparation
AC adaptor or voltage regulator
Frequency counter
2. Adjustment procedure
(1) Connect SYF (CP355) and GND (CP344).
(2) Monitor HDB (CP301) with frequency counter and adjust VR320 so that frequency becomes 15.734 ±
0.1 KHz.
(3) After completing adjustment, disconnect SYF (CP355) and GND (CP344).
5-2. VCOM AC adjustment and VCOM DC coarse adjustment
1. General
Perform these adjustments after D PCB or LCD module is replaced.
2. Preparation
AC adaptor or voltage regulator
Digital oscilloscope
3. Adjustment procedure
(1) Make sure amplitude of VCOM output (CP340) is 5.15 ± 0.30 Vp-p.
(2) Adjust VR321 so that maximum VCOM output (CP340) will be 3.60 ± 0.20 V.
4. Connection diagram
Power supply
D-PCB
QV-2900
VCOM
(PC340)
High level
3.60 [V]
0 [V]
–1.55 [V]
Amplitude
5.15 ± 0.30
[VP-P]
Oscilloscope