Specifications

— 15 —
3-4. VCO free run frequency adjustment
Room temperature should be 20 ± 10 ºC
1. Preparation
AC adaptor or voltage regulator
Frequency counter
2. Adjustment procedure
(1) Connect CP733 (SYF) and CP700 (GND).
(2) Monitor CP704 (HDB) with frequency counter and adjust VR755 so that frequency becomes
15.734 ± 0.1 KHz.
(3) After completing adjustment, disconnect CP7033 (SYF) and CP700 (GND).
3. Notes
When unable to adjust using AC adaptor, use voltage regulator and supply power to be VCC-1-1
(CP149) = 5.0 ± 0.05 V.
3-5. BL drive voltage adjustment
1. Preparation
AC adaptor or voltage regulator
Multimeter
2. Adjustment procedure
Make sure that CP910 (BL-VCC) is within 5.4 ± 0.2V.
3. Notes
When unable to adjust using AC adaptor, use voltage regulator and supply power to be VCC-1-1
(CP149) = 5.0 ± 0.05 V.
3-6. VCOM AC adjustment and VCOM DC coarse adjustment
1. Preparation
AC adaptor or voltage regulator
Digital oscilloscope
2. Adjustment procedure
(1) Make sure amplitude of VCOM output (CP176) is 6.6 ± 0.3 V.
(2) Adjust VR320 so that maximum VCOM output (CP716) will be 4.8 ± 0.2 V.
3. Notes
When unable to adjust using AC adaptor, use voltage regulator and supply power to be VCC-1-1
(CP149) = 5.0 ± 0.05 V.
Power
Supply
L-PCB
QV-7000SX
VCC1-1
(CP149)
VCOM
(CP716)
High level
4.8 [V]
0 [V]
–1.8 [V]
amplitude
6.6 [V]