Specifications

— 16 —
2.85V ± 0.05V
(pedestal-10 step)
3.5 ± 0.05V
(pedestal-pedestal)
3-7. Brightness voltage setting and contrast adjustment
1. Preparation
AC adaptor or voltage regulator
Digital oscilloscope
2. Adjustment procedure
(1) Start up Test mode Menu1.
(2) Select GRAY SCALE (10 step).
(3) Trigger VB waveform (CP335) by FRP (CP346) signal to adjust as noted below.
(4) Adjust RGB-AMP VR (VR340) so that pedestal-pedestal voltage of VB(CP335) signal is 3.5 ±
0.05 V.
(5) Adjust contrast VR (VR344) so that contrast terminal voltage (CP305) is 3.0 ± 0.05 V temporary.
(6) Adjust Bright VR (VR381) so that potential between VB (CP335) signal’s pedestal and 3 step is
2.20 ± 0.05 V.
(7) Adjust contrast VR (VR344) so that potential between VB (CP335) signal’s pedestal and 10 step
is 2.85 ± 0.05 V.
Make sure that waveforms are not distorted.
3. Notes
When unable to adjust using AC adaptor, use voltage regulator and supply power to be VCC-1-1
(CP149) = 5.0 ± 0.05 V.
3-1 3-2
L-PCB
VCC1-1
(CP149)
VB
(CP335)
Figure 3-1, 3-2
QV-7000SX
Power
Supply
Digital oscilloscope