Specifications
— 5 —
1-2. White balance · Sensitivity adjustment
• Set QV-7000SX to “REC” mode.
• Normal Recording mode ( ).
• Light box.
1. Preparation
(1) PC (IBM Compatible)/OS: Windows 95.
(2) Link cable.
(3) Adjustment program ADJ778K.EXE.
(4) Stabilizer.
(5) Viewer (Kenko light box handy 5000) (Modified in order to input DC externally)
(6) Use two ND filter together, one ND10 and one ND20.
Use two color temperature converter filter together, one LA10 and one LA20.
2. Adjustment procedure
(1) Start test mode MENU2.
✻ Refer to TEST MODE on page 17 and 18.
(2) Select “CCD ADJUST”.
Press +/– to select and SHUTTER button to display “SHUT TO START”
(3) White balance adjustment.
Set the color temperature converter filters LA10 and LA20 above the light box.
(4) Set camera lens toward light source then press the shutter button.
(5) When RGB ADJ COMPLETE is displayed, the adjustment of white balance is completed.
(6) Sensitivity Adjustment.
Remove two color temperature filters from simplified viewer then set the filter so that center of
illuminance face and center of two ND filters are lined up.
(7) Set camera lens toward light source then press the shutter button.
(8) When SENS ADJ COMPLETE is displayed, the adjustment of sensitivity is completed.
Turn off the unit once.
(9) Compensation program.
Connect QV-7000SX and PC with a link cable.
Set the camera in PLAY MODE.
(10) Execute compensation program (ADJ778K) on Windows 95.
(11) Click “Replace TEST”.
(12) “Replacement Complete” is displayed.
Turn power off.
No. 1
No. 2
PROGRAM
CCD RGB ADJUST
CCD SENS ADJUST
Color temperature (K)
light source 1
4400 ± 200
Light intensisty (cd/m
2
)
light source 2
50 ± 5
Note
No specified figure
for light intensity
No specified figure
for color temperature
Light source (viewer)