Also, please perform a Flag Clear after making changes to I/O Parameters.
The Flag Clear operation sequence is on the following page.
FLAG CLEAR OPERATION on QT series:
1) Turn off the machine (power switch located on the left hand side of the
machine behind the operator display – see Fig 1 below for reference)
2) Hold down the DISPLAY ON/OFF button located on the bottom right hand
front side of the QT-6000 (refer to Fig 2 below for reference) and turn the
power ON
3) Release the DISPLAY ON/OFF key once the following display comes ON
4) Depress the OK button
5) When the FLAG CLEAR screen option appears, depress YES to complete
Flag Clear operation