Edge HV Series Quick Start Guide

© 2013 Castle Creations, Inc. P/N: 095-0232-00 Revision Date - 03/2013 PAGE 1 of 2
SETTING 1: LOW VOLTAGE CUTOFF BATTERY CELL CUTOFF VOLTAGE*
Option 1: 3.0V per cell
Option 2: 3.1V per cell
Option 3: 3.2V per cell (Factory Setting)
Option 4: 3.3V per cell
Option 5: 3.4V per cell
Option 6: DISABLED
SETTING 2: BRAKE TYPE
Option 1: Soft Delayed Brake
Option 2: Hard Delayed Brake
Option 3: Soft Brake – No Delay
Option 4: Hard Brake – No Delay
Option 5: Brake Disabled (Factory Setting)
SETTING 3: LOW VOLTAGE CUTOFF TYPE
Option 1: Hard Cutoff
Option 2: Soft Cutoff (Factory Setting)
Option 3: RPM decrease
Option 4: Pulsing RPM ESC pulses throttle
SETTING 4: PWM SWITCHING RATE**
Option 1: 8kHz outrunners
Option 2: 12 kHz (Factory Setting)
Option 3: 16 kHz
OPTIONAL STICK PROGRAMMING
1. Power ESC with TX throttle stick (stick) in the top position (full throttle).
LED will repeat a quick single flash.
2. Move stick to the middle. Phoenix Edge will emit a short tone, and LED
repeats a quick double flash. Repeat high / medium through to a triple
flash.
3. ESC sounds four short tones, and the LED will repeat a long single flash.
4. Step through settings and values by answering “yes” (full throttle) or
“no” (low throttle). The setting and value are “flashed” out by the LED.
Example: setting #3 value #2, = 3 beeps/flashes, then 2 beeps/flashes. Answering “no” moves to the next value. A “yes”
answer is signaled by rapid LED flashes and a constant beep.
5. Move the stick to the middle position to move to next setting. Repeat steps 4 and 5 as needed.
6. Once the desired settings are entered, remove and reconnect power. Arm speed control as normal.
Stick programming offers quick access to basic settings only. Many more settings may be accessed using Castle Link and a
Windows PC.
*Refer to cell vendor’s instructions for cutoff voltage.
**Refer to motor manufacturer’s instructions for frequency settings.