GENERATOR OPERATION
Optimal Generator Operating
Conditions
• Temperature: 23
o
F to 104
o
F
(-5
o
C to 40
o
C)
• Humidity below 95%
• Height above sea level: < 3280 feet
(1,000 m). If the height of the operating
area is over 1,000 m high, output power
will be reduced.
Connection to Household Power
Supply
This generator must be installed in accordance
with all applicable local laws and electrical
codes. The generator must be isolated from the
utility and the connection must be verified by a
qualified electrician.
Generator Grounding
The National Electrical Code requires generators
to be grounded to an approved earth ground.
Correct grounding for the generator is necessary
for optimum engine performance and reduces
the risk of electric shock. Use the ground
terminal to properly ground the generator.
Before using the ground terminal, consult
a
qualified electrician, electrical inspector, or local
authority having jurisdiction for local codes or
ordinances that apply for the intended use of the
generator.
1. RP3600 Earth Ground
2. RP5500, RP6500 E, RP7500 E Earth
Ground
AC Usage
Do NOT overload the generator. Exceeding the
rated power of the generator can damage the
generator and the electrical devices connected
to it.
Motor-driven devices require a large starting
current. Make sure that the total power
requirement of these types of loads does not
exceed the rated power of the generator.
When the generator is used to power multiple
loads or electric appliances, start by connecting
the appliance with the highest starting power
requirements, followed by the second highest
and ending with the lowest.
High Altitude Kits
At higher altitudes, the standard air-fuel mixture
is too rich and will cause decreased
performance and increased fuel consumption. A
rich mixture will also foul the spark plug and
make starting difficult. Operation at higher
altitudes for extended periods of time may
increase emissions.
Proper operation can be ensured by installing an
altitude kit when required. High altitude kits
should be installed by a qualified technician.
Contact an authorized service provider if the
portable generator will be operated at altitudes
greater than 3000 feet (0.9 km) above sea level.
Note: At elevations greater than 8000 feet
above sea level, the engine may experience
decreased performance even with the high-
altitude kit installed.
BEFORE STARTING ENGINE
Engine Oil
Check the oil level before each use. Refer to the
Engine Oil - Check procedure in this manual.
1
2