STORAGE
When a generator is in storage, air may
condense and moisture may appear on the
windings. In order to minimize condensation,
always store the generator in a dry area. Cover
the generator with a protective cover that
extends to the ground. The cover should remain
loose around the generator in order to allow
proper ventilation.
Storage for 1 to 3 months
Remove any dirt, rust, grease, and oil from the
generator. DO NOT use a pressure washer to
clean the generator. Inspect the exterior. Make
any necessary repairs.
Add fuel stabilizer to the fuel tank to prevent the
gasoline from going bad. Start and run the
engine for 10 minutes to ensure that the fuel
stabilizer has been pulled in to the carburetor.
Shut off the engine and allow the engine to cool.
Turn the fuel valve to the off “O“ position.
Move the generator to the storage place.
Attach the trickle charger to the port in the
control panel and to standard AC power to keep
the generator battery fully powered for easy start
after storage. Disconnect the battery charger
once the battery is fully charged (indicated by a
green light on the charger).
Cover the generator.
Storage for more than 3 months
Remove any dirt, rust, grease, and oil from the
generator. DO NOT use a pressure washer to
clean the generator. Inspect the exterior. Make
any necessary repairs.
Gasoline is extremely flammable and is
explosive under certain conditions. Drain the fuel
in a well-ventilated area with the engine stopped
and cool. Never smoke or allow flames or sparks
in the area during
this procedure.
Drain the fuel from the fuel tank into a suitable
container using a manual siphon pump. DO
NOT save the fuel for future use in the
generator. Turn the fuel valve to the on “I“
position. Start and run the engine until the
engine stops, to allow the fuel to drain from the
fuel lines and engine system. Turn the fuel valve
to the off “O” position. Apply a small amount of
oil to the threads on the fuel tank filler neck and
install the cap.
Change the engine oil. Refer to Engine Oil and
Oil Filter – Change.
Remove both spark plugs and pour a small
amount of oil into both cylinders. Install the
spark plug but do not install the spark plug cap.
Move the generator to the storage place.
Attach the trickle charger to the port in the
control panel and to standard AC power to keep
the generator battery fully powered for easy start
after storage. Disconnect the battery charger
once the battery is fully charged (indicated by a
green light on the charger)
Cover the generator.