Operating Guide

6
California Health and Safety Code 119080
Electrical backfeed into a utility’s distribution system
can cause property damage, severe injury, or death.
Do not connect generator to a buildings electrical
system until after the building’s main switch has been
used to isolate the building from the utility power
system. For permanent installations, connection shall
only be by means of a double throw switch as to isolate
the building from utility power system. Consult a
qualified technician for proper use and installation.
Comply with all applicable laws and electrical codes.
Additional Messages
Do not operate in wet
conditions
No smoking, no exposed
flames, no sparks.
Maintain a minimum distance
of 5 feet (1.5 meters) from
other objects.
Ensure that the unit is
properly grounded.
Eye protection must be worn
at all times.
This way up. Always keep
upright.
Recyclable – Follow local
recycling & reclaiming
procedures.
Never dispose of battery.
Take to designated waste
reclamation site.
Danger: Explosive Gases.
Danger: Battery Acid –
Corrosive and poisonous.
Special Requirements
Electrical equipment, including lines and plug
connections should be covered and protected
from moisture.
In any generator set installation, the frame of the
generator must be connected to an earth
ground. A ground terminal is provided.
The RP12000 E has a permanent neutral
conductor between the stator winding and the
frame.
For 120VAC, use extension cords rated for 125V
at 20A or greater. For 240VAC, use extension
cords rated for 250V at 30A or greater. Use the
shortest extension cord that meets these
requirements.
Wear a hard hat, protective glasses, and
other
protective equipment, as required.
When work is performed around an engine
that is
operating, wear protective devices for
ears in order
to help prevent damage to
hearing.
Do not wear loose clothing or jewelry that can
snag
on controls or on other parts of the
engine.
Ensure that all protective guards and all
covers are
secured in place on the engine.
Never put maintenance fluids into glass
containers. Glass containers can break.
Use all cleaning solutions with care.
The circuit breakers should match the generator
specifications. If the circuit breakers require
replacement, they must be replaced with a
circuit breaker of the same rating and
performance characteristics.