Operating Guide

8
Lifting Eye Assembly
1. Align the mounting holes of the lifting
eye (3) with the mouting holes in the
frame.
2. Place one washer (2) on each 10 mm
bolt (1) and insert through each
mounting hole.
3. Install and hand tighten one 10 mm nut
(4) on each bolt.
4. Tighten both nuts to 26 ± 2 lb ft
(35 ± 3Nm).
Handle Assembly
1. Install the foam grip (3) onto the handle
(4).
2. Insert one plug (1) into each end of the
handle (4).
3. Align the mounting holes of the handle
(4) to the mounting holes of the frame.
4. Insert one 8 mm bolt (5) through each
mounting hole.
5. Install and hand tighten one 8 mm nut
(2) on each bolt.
6. Tighten the nuts securely.
Battery Connection
The generator is packaged with a valve
regulated and maintenance free lead acid
battery. The generator is packaged with the
battery mounted in the battery holder. To
connect the battery:
1. The unit ships with the positive battery
cable (1) already connected.
2. Attach the cable with the black cap (2)
to the negative battery terminal.
NOTE: Replace battery only with the same part
number. Use of a non-conforming battery can
create a fire hazard.
Oil
Follow the Engine Oil Level-Check procedure to
add the proper amount of oil for the unit as
described in the Specifications chart.
2
1
4
3
2
1
5
4
2
3
1