Owner`s manual

17 REV 46512-20110301
ENGLISH 46512
MAINTENANCE AND STORAGE
Generator Maintenance
Make certain that the generator is kept clean and stored
properly. Only operate the unit on a flat, level surface in
a clean, dry operating environment. DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapors.
Storage
The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
longer term storage, please follow these guidelines.
Generator Storage
1. Allow the engine to cool completely before storage.
2. Clean the generator according to the instructions in
the Maintenance section.
3. Turn the Fuel Valve to the “OFF” position.
4. Be sure all appliances are disconnected from the
generator. Start the engine and let it run until the
fuel in the line and the carburator is consumed and
the engine dies.
5. Press the Battery Switch to “OFF”.
6. Add a fuel stabilizer into the fuel tank.
7. Change the oil.
8. Remove the spark plug and pour about ½ ounce
of oil into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.
9. Reattach the spark plug.
10. Store the unit in a clean, dry place out of direct
sunlight.
Use a damp cloth to clean exterior surfaces of the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.
DO NOT use a garden hose to clean the generator.
Water can enter the generator through the cooling
slots and damage the generator windings.
CAUTION
Disconnect the Battery
1. Remove the protective cover from the black/negative
battery lead.
2. Disconnect the black/negative lead from the black/
negative terminal on the battery and store the cap
screw (M6x10) and lock washer (M6).
3. Repeat steps 1-2 for the red/positive battery lead.
4. Store the battery in a cool, dry place.
Charge the Battery
For generators equipped with batteries for electric
starting, proper battery maintenance and storage
should be followed. An automatic battery charger with
automatic trickle charging capability should be used to
charge the battery. Maximum charging rate should not
exceed 1.5 amps. Follow the instructions included with
the battery charger. The battery should be fully charged
at least once per month.
Generator exhaust contains odorless and colorless
carbon monoxide gas.
To avoid accidental or unintended ignition of your
remote start generator during periods of storage,
the following precautions should be followed:
When storing the generator for short periods of
time make sure that the Ignition Switch, the Fuel
Valve and the Battery Switch are set in the OFF
position.
When storing the generator for extended periods
of time make sure that the Ignition Switch, the
Fuel Valve and the Battery Switch are set in the
the the OFF position and the battery leads have
been disconnected from the battery.
DANGER