Specifications
10 Chapter 3. Alignment
9mm diode
5.6mm diode
Lens
Retaining
ring
Figure 3.1: Lenstube assembly,showing diode,lens, andmounting hard-
ware.The same tubecan be usedfor 5.6mm and9mm diodes. Note that
your lens tube may have alignment adjustment screws.
Figure 3.2: Image showing collimation tubes.
doesnotcontactthediode. Alsoensurethelensistight;if
not,usePTFEtapeonthelensthreads. Twolayersofthick
tape (90µm as used for gas plumbing) is good.
6. Mount thelenstube inaholder ormountthat allowsrotation
of the entire assembly around the long axis.
7. Apply powerto thediode, abovethreshold butwell belowthe
maximum permissible current.
8. Approximatelyfocus at several metres distance. Itmay be
helpfultoreflectitfromamirrorandbacksothatyoucan
adjustthealignmentandseetheeffectnearby. Youshould
adjustfocusuntilyouseeacleansymmetricellipseatthis