Specifications

LCY-07084A-8
[Note7-4] Apply to terminal of R0R5,G0G5,B0B5,SPR,SPL,CK,LS and LBR.
[Note7-5] Apply to terminal of CLS,SPS,MODE1,MODE2 and U/L.
[Note7-6] Please switch polarity of amplitude COMAC by center value of amplitude that is COMDC
for every one level scan and every one vertical scan. Moreover, please adjust COMDC so
that contrast becomes the maximum and a flicker becomes the minimum for every module.
7-2) Backlight unit driving section
Table7-2
Parameter Symbol MIN TYP MAX Unit Remarks
LED voltage Vf 16.0 17.3 21.3 Ta=25,If=90mA
LED voltage Vf-30 22.8 V Ta=-30,If=90mA
difference of lines of LED voltage Vf 1.4
LED current If 90 95 mA
Power consumption Wf 5 W