Specifications
LCY-07084A-19
Table14-1 Reliability test conditions
Table 12 Temperature condition is based on operating temperature condition
No. Test items Test condition
1 High temperature strong test Ta = +85℃ 240h
2 Low temperature strong test Ta =−40℃ 240h
3 High temperature and high
humidity operation test
Tp = +60℃, 90%RH 240h
4 Hi temperature operating test Tp = +85℃ 240h
5 Low temperature operating test Ta =−30℃ 240h
6 Electro static discharge test ±200V・200pF(0Ω) 1 time for each terminals
7 Shock test 980m/s
2
・6ms, ±X;±Y;±Z 3 times for each direction
(JIS C0041, A-7 Condition C)【caution】
8 Vibration test Frequency : 8∼33.3Hz , Stroke : 1.3mm
Frequency : 33.3Hz∼400Hz,Acceleration : 29.4m/s
2
Cycle : 15 minutes
X,Z 2 hours for each directions,4 hours for Y direction
(total 8 hours) 【caution】(JIS D1601)
9 Heat shook test −30℃ ∼ +85℃ / 200 cycles
(0.5h) (0.5h)
【Note】 Ta = Ambient temperature, Tp = Panel temperature
【Check items】 In the standard condition, there shall be no practical problems that may
affect the display function.
【caution】 Definition of X,Y,Z direction is shown as follows
X
Y
Z