Specifications

LCY-07084A-19
Table4-1 Reliability test conditions
Table 12 Temperature condition is based on operating temperature condition
No. Test items Test condition
High temperature strong test Ta = +85 240h
Low temperature strong test Ta =40 240h
High temperature and high
humidity operation test
Tp = +60, 90%RH 240h
Hi temperature operating test Tp = +85 240h
Low temperature operating test Ta =30 240h
Electro static discharge test ±200V200p(0) 1 time for each terminals
Shock test 980/s
2
6ms ±X;±Y;± 3 times for each direction
JIS C0041, A-7 Condition Ccaution
Vibration test Frequency : 833.3Hz , Stroke : 1.3mm
Frequency : 33.3Hz400Hz,Acceleration : 29.4m/s
2
Cycle : 15 minutes
, 2 hours for each directions4 hours for direction
(total 8 hours) cautionJIS D1601
Heat shook test 30 +85 / 200 cycles
(0.5) (0.5)
Note Ta = Ambient temperature, Tp = Panel temperature
Check items In the standard condition, there shall be no practical problems that may
affect the display function.
caution Definition of X,Y,Z direction is shown as follows