Specifications

LCY-07084A-6
5-2Backlight fluorescent tube driving part
Table5-4
Pin No. Symbol Description Remarks
1 A1 Input terminal (Anode 1)
2 A2 Input terminal (Anode 2)
3 NC
4 K1 Input terminal (Cathode 1)
5 K2 Input terminal (Cathode 2)
6 K3 Input terminal (Cathode 3)
7 NC
8 NC
(6) Absolute maximum ratings
Teble6-1 Absolute maximum ratings GND=0V
Parameter Symbol MIN MAX Unit Remark
Analog VSHA 0.3 +6.0 Ta=25 Power supply
of source driver
Digital VSHD 0.3 +6.0
Power supply VDD 0.3 +35.0
of gate driver VCCVSS 0.3 +6.0
VEEVSS 0.3 +35.0
VDDVEE(VSS) 0.3 +35.0
Input signal Digital VID 0.3 VSHD+0.3 ,[Note6-1]
Analog VIA 0.3 VSHA+0.3 ,[Note6-2]
Common electrode
driving signal
VCOM 4 +6
Storage temperature stg 40 85 [Note6-3,4]
Operating temperature
(LCD panel surface)
opr1 30 85 [Note6-5,6]
Operating temperature
(Ambient temperature)
opr2 30 65 [Note6-6]
Current of LED If 150 mA Ta=25
[Note6-1] SPLSPRR0R5G0G5B0B5LSCKLBRMODE1MODE2U/LSPSCLS
[Note6-2] V0V1V2V3V4V5V6V7V8V9V10
[Note6-3] This rating applies to all parts of the module and should not be exceeded.
[Note6-4] Maximum wet-bulb temperature is 57. Avoid dew condensation on the module.
Otherwise electrical current leaks will occur , and it cannot meet the specifications.
[Note6-5] The operating temperature guarantees only operation of the circuit. For contrast, speed of
response, and other factors related to display quality are determined in the circumstances
with Ta=25.
[Note6-6] Ambient temperature when the backlight is lit (reference value).