Instructions / Assembly
Table Of Contents
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual-1
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.2
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.3
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.4
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.5
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.6
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.7
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.8
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.9
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.10
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.11
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.12
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.13
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.14
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.15
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.16
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.17
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.18
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.19
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.20
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.21
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.22
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.23
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.24
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.25
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.26
- Cavaliere_AP238_Series_PSD_F_L_Z_Wall_Manual.27
- Back

Page 13
Controls:•
Adjusting the timer function:•
While the blower (motor) is not running, press and hold • Decrease Value button over 3 seconds to
enter timer mode. Adjust to desired period of delay off timer by pressing Increase Value or Decrease
Value button (minimum 1 minute to maximum 9 minutes). This setting will be saved immediately.
Activating the timer function:•
While the blower (motor) is running, press and hold • Power button for over 3 seconds to activate
delay off timer. Power-Off Delay Digital Timer begin to countdown, when it reaches zero, the blower
(motor) will shut down.
Adjusting the light:•
Press • Light button once to turn on the lights, and once again to turn off the lights.
While the lights are off, press and hold • Light button for over 3 seconds to dim the lights from high to
low. Level of brightness will be stored in system’s memory.
CAUTION: DO NOT touch the lights until switched OFF and cooled.
Note: Light settings are independent from other settings (including power-off delay) and lights has to be
manually turned on or off.
Note: The system saves user congurations, settings such as light, timer and blower (motor) speed will re-
main the same the next time it is turned on.
Range Hood Operations (Continued)
Power
Power-Off Delay
Decrease Value
Light
Increase Value
Blower Speed Indicator
Power-Off Delay Digital Timer
Cleaning Reminder Indicator