User manual

G
G
Speed Dome Camera Instruction Manual
41/74
Alarm Input Setup
ALARM INPUT SETUP
------------------------
ALARM NO. 1
TYPE N.OPEN
ACTION NOT USED
HOLD TIME ENDLESS
POST ACTION HOME
BACK
EXIT
Defines Alarm Function. When an alarm is receive, an
input signal to the camera triggers the user-
defined action
programmed for the alarm.
z Alarm No
[1~3]
Selects a sensor number to set up.
z Type
[Normal OPEN/Normal CLOSE]
Selects sensor operation type.
z Action
[NOT
USED/PRESET/PATTERN/SWING/GROUP]
Selects an action to run when a sensor
signal is input.
z Hold Time
[ENDLESS / 1~59 SEC. / 1~180 MIN.]
Sets the time period for the action which is
run by external sensor activati
on. After the
time period passes, the action pre-
defined
in Post Action runs sequentially
in
succession to the action by external sensor
activation
. If this option is set to
ENDLESS, Post Action
does not
activate.
z Post Action
[HOME/PRESET/PATTERN/SWING/GROUP
/PREV ACTION]
Selects the action that a camera will run
after the time period inHOLD TIME
passes. If Post Action is set to
PREV.
ACTION
, the camera runs the previous
action which it ran most recently.
OSD MENU
4