Portable Air-conditioner GLA-08C Use and Care Manual Thank you very much for selecting this new model of Portable Air Conditioner, please read this Use and Care Manual carefully before installing and using this appliance. Please keep this Use and Care Manual properly for future reference.
Contents Safety Instructions.....………………………………….……………………………………………………………….…1 Function and Technical Specification….……………..……………………………………………………………...…. 3 Identification of Parts…………...…………………………………………………………………….……………………3 Operation and Settings……………….……………………………………………………………………………………4 Protection………………………..………………………………………………………………………………..…………9 Handling and Transportation……………...……………………………………………………………………………….9 Installation and Adjustment ……………….…………………………………………………………..…………………9 Drainage Instruction…………………………..
Safety Instructions 1. Electrical Specifications 1. All wiring must comply with local and national electrical codes and be installed by a qualified electrician. If you have any questions regarding to the following instructions, please contact a qualified electrician. 2. The unit must be installed in accordance with national wiring regulations. Check available power supply and resolve any wiring problems before installation and operation of this unit. 3.
3. Cautions ※ Keep the unit at least 1 meter away from TV or radios to avoid electromagnetic interference. ※ Do not expose the unit under direct sun light to avoid surface color fading. ※ Do not tilt the unit for more than 35 degrees or upside-down while transporting. ※ Place the unit on a flat surface and upright with less than 5 degrees inclination.
Function and Technical Specification ※ This unit offers cooling, dry, fan and sleep modes, ideal for home and office use. ※ This unit is with two fan-speed level accessible by panel control and remote control. ※ Temperature setting range of this unit is 62.6-86℉(17-30℃) .. ※ This unit is designed with various protection functions such as 24-hour programmable timer, auto condensate circle, super intelligent temperature sensor and water-full control and warning etc.
Identification of Parts 17 12 13 14 18 15 11 16 19 1. Control panel 13. Upper drain hole and plug 2. Vertical louvers 14. Power cord storage 3. Horizontal louvers 15. Lower filter 4. Horizontal louvers connecting rod 16. Lower drain hole and plug 5. Air outlet frame 17. Handle 6. Front shell 18. Air discharge and protective vent 7. Universal wheel 19. Chassis 8. Back shell 20. Remote control 9. Central connecting rod 21. Exhaust hose assembly 10. Vertical louvers connecting rod 22.
Operation and Settings This section explains proper mobile air conditioner operation. 1. Control Panel On/Off button Mode button Up button Timer button Fan speed button Down button Fan speed Timer indicator Water-full indicator indicator Fan mode Cool mode Dehumidify mode indicator indicator Sleep mode indicator Power indicator LED display window Timer indicator Remote control signal receiving window Celsius/Fahrenheit temperature indicator 2.
Under cooling mode, press “Timer” + “ 3) ” buttons together, the unit auto enter into “Sleep” Mode. Adjust temperature The temperature can be set within a range of 62.6-86℉(17-30℃) under cooling mode. Press or Press and buttons to increase or decrease the temperature 1.8℉(1℃) by pressing once. buttons together to convert Celsius degrees and Fahrenheit degrees and corresponding indicator will light up.
3. Remote Control Operation The Remote control transmits the signal to system. Button: press this button to start unit when it is energized or stop the unit when it is in operation. Button: press this button to set unit automatic on and off time Button: press this button to select high speed of fan running (except dry and sleep modes) Button: press this button to select low speed of fan running. Button: press this button to increase temperature or timer setting.
control if the batteries have any leakage. If you eat the liquid from the batteries, brush your teeth and see doctor. The chemicals in batteries could cause burns or other health hazards. Multiple Protection Functions 1. Anti-freeze protection function Compressor, water spraying motor will turn off when compressors running over 10 minutes and tube temperature (Tp) is continuously ≦35.
This air-conditioner may be moved indoors conveniently; keep the unit in upright position while moving it. The air-conditioner shall be placed on flat surface. Do not install or operate this air-conditioner in bathroom or other wet environments. 1.1 Installation of exhaust hose assembly and its adapter 1) Take out the exhaust hose assembly and its adapter from plastic bag. 2) Extend the exhaust hose at one end, screw the round end of adapter into exhaust hose at anticlockwise direction (as Photo)).
Keep the right direction of slant side A of adapter, for ease installation of window seal-plate. Keep exhaust hose assembly be strongly locked by fasteners in exhaust outlet to avoid its fall off 1.3 Installation of window seal-plate 1) Open the window in half, put the seal-plate into window, determine in vertical or horizontal position according to window open direction. (As Photo) 2) Extend seal plate parts, adjust it to the length of window and fix it with screws then.
B. Lock self-tapping screw φ4 mm into adapter hole. Remarks: Slide the adapter downwards and assure the adapter installed in good position. Lock the screw tightly to avoid fall off. Exhaust hose can’t be bent or with flexure higher than 45 degrees, in order to keep good ventilation of exhaust hose. Important notes: The exhaust hose is 280mm-1500mm long and which is determined by the specification of the air-conditioner (s).
Drain Cover Drain Hole 2. Continuous drain: 1) Screw off the drain cover and unplug the water stopper (as Photo). 2) Connect drain-hole with φ13mm PVC drain hose, as deep as possible to avoid leakage (as Photo). 3) Pull the drain hose to bathroom or outdoor. Notes: Drain hose must be installed before unit starts working. It is suggested to use manual drainage when unit in cooling mode, to ensure enough water to recycle in the unit to cool condenser and enhance cooling performance.
Handle position ` Handle position Clean the filters gently in warm water (about 104℉(40℃)) mixed with detergent, and dry in the shade (as Photo). push filter in even force gently into correct place to avoid any damage. Notes: Do not squash the mesh. Do not hit the mesh with sharp objects or brush. End of Season Storage 1. Screw off the drain cover, and then pull out the stopper to drain water completely. Note: the tilt angle of the unit must be≦30 degrees. 2.
Troubleshooting Please check the unit and suggestions below before asking for professional service, but never dismantle or repair the unit by yourself, it may cause harm to you and your property. Trouble Cause Power supply failure The unit fails to start up The compressor does not work The remote control does not work LED displays error code “E1” LED displays error code “E2” LED displays error code “E4” Water-full lights indicator turn it on. Drain the water stored in the unit.
Appendix Fuse parameters Model: FSD or 50F Voltage: 250V Current: 3.15A Schematic diagram of the air conditioner Capillary Conden ser Compre ssor Evapor ator For specific technical parameters of the model, refer to rating label on the product. Correct Disposal of this product This marking indicates that the product should not be disposed with other household wastes throughout the world.