Page:2/14 CONTENTS 1.IMPORTANT SAFEGUARD ……………………….…... .3 2.FEATURES AND PARTS LIST………………………….…. 4 3.INSTALLATION …………………………………..…. …….... 6 4.CONTROL AND SETTING……………………………………8 5.WATER-DRAINAGE…………………………………………..11 6.MAINTENANCE………………………………………………..12 7.TROUBLE SHOOTING………………………………………..13 8.APPENDIX……………………………………..……………….
Page:3/14 Thank you for selecting this new model portable air conditioner. Please safely keep this user manual for you later reading, and be sure to read this manual carefully before using the unit. IMPORTANT SAFEGUARDS Important Safeguards. ·The appliance is for indoor use only. ·Read all instructions, Rated Power Supply: Please connect the unit with Grounded Power Sources: 110-120VAC, 60HZ. ·Disconnect the power plug before dismantling, assembling or before cleaning.
Page:4/14 FEATURES AND PARTS LIST 1、Features Self evaporative system, no water tank. Oval and thin design, looks unique and luxury. Wing outlet closes automatically after shut down the unit, prevent dirt into machine. LCD display, indicating temperature and operation status. ·Remote control and power plug can be put in the rear of the unit after use, exhaust hose could be fixed with the machine after use.
Page:5/14 2、Parts list: ① ② ③ ④ ⑨ ⑥ ⑩ ⑤ 13 ⑦ 11 ⑧ 12 14 15 16 1. Tope cover 2. Air outlet grille 3. Control panel 4. Front cover 5. Caster 6. Handle 7. Power cord 8. Drain port 9. Up filter frame 10. Protective net 11. Down filter frame 12. Water plug 13. Remote control 14. Exhaust hose 15. Window kits 16.
Page:6/14 INSTALLATION 1. Installation Warning:Before using this unit, please keep it upright at least 2 hours. The unit can be moved easily among the rooms, but please note the following: 1.1 Assemble hose adaptor(picture 1) (picture 1) 1)Prepare male and female parts of hose adaptor, they are almost same on the structure 2)Each hand hold one part, you can connect them easily. Remark: Don’t push too hard to prevent damage. 1.
Page:7/14 1.4 Please make sure the unit is upright. The unit should be put on the flat floor and 50cm to around objects. (Picture 5) Fix the other end of the heat-exhausted hose to the air-outlet window kit(picture6, 7) (Picture 6) (Picture 7) Important safeguards The length of the soft hose is from 280 mm to 1500 mm which bases on the unit model. Don’t use the lengthened hose or other hoses instead, or it might cause faults.
Page:8/14 CONTROL AND SETTING This portable air conditioner of cooling only model has three functions: cooling, dehumidifying and fan. If the machine you purchased is cool and heat model, it has four functions cooling, heating, dehumidifying and fan Fan has three speeds: high speed, middle speed and low speed, Setting temperature is 18--300C, 24 hours timer, water-throwing function, sensor and water-level protective function.
Page:9/14 available when the unit on; auto-run timer is only available when the unit is off. After timer setting accomplishes effectively, icon will keep on flashing until setting time is due. If set again, history record will be cleared. 1.6 Up and Down button: can set temperature and timer . Under cooling or heating mode, the sting temperature ranges from 18~30℃/64~86℉. If press Up ℉. 1.
Page:10/14 5.Fan :Press this key to set low/middle/high fan speed. 6.Swing :Press this key to control swing function. 7.Temperature 8.Sleeping :Press this key to choose Centigrade or Fahrenheit. (Only under cooling function):Press this key to enable this function. 9.Timer :Press this key to set time. Within 5 hours, time interval is half hour; from 5 hours to 24 hours, time interval is 1 hour. Once set number will flash 5 times as confirmation . 10.
Page:11/14 WATER-DRAINAGE 1.Manual drainage : 1.1 When water tank is full and unit stop working, please shut off the unit and unplug Please don’ t move the model sharply, or the water will spilt out from water received plate. 1.2 Use a water container to take water under the water plug. 1.3 Screw off the water plug and unplug the water blocker, water will come out to the water container. 1.4 Stuff up the water blocker and screw down the water plug. 2. Continue drainage: 2.
Page:12/14 Maintenance Cleaning. Please shut off the unit and unplug the plug before cleaning or maintenance Clean the surface Clean the housing with a duster or a soft wet cloth. Do not use chemical solvent (such as benzene, alcohol, gasoline). The surface may be damaged or even the whole case may be deformed. 1. Air filter cleaning 1.1Clean the air filters every 2 weeks. If the air filter is blocked with dust, the efficiency will reduce.
Page:13/14 Trouble Shooting Don’t repair or disassemble the unit by yourself, unsuitable repair may make the quality-protected card in vain, and even cause damage to the user or his/her possession.
Page:14/14 APPENDIX Fuse Parameter Type: FSD or 50F Voltage: 115V Current: 10.9A The working principium diagram of the unit: Capillary tube Condenser Compressor Evaporator There is no further notice for the change of the parameters above, the exact parameters base on the rating plate. Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
SERVICE CENTER 1941 S. Vineyard Ave unit 6 , Ontario, CA 91761 Tel:(888)470-7342 Fax:909-974-2865 Hours:8:30AM-5:00PM PST TO OBTAIN WARRANTY SERVICE Contact CCH Technical Suport Email:TechSupport@cchappliance.com Phone:(888)470-7342 From 8:30AM to 5:00PM Monday through Friday Pacific Time. WARRANTY PERIOD: Labor: 1 Year from the Date of Purchase. Parts: 1 Year from the Date of Purchase. Compressor: 3 Years from the Date of Purchase.