1.0  SPECIAL NOTICES
1.1  The following special notices highlight 
important information in the installation and 
maintenance sections. Each serves a special 
purpose and is displayed in the format shown:
This symbol indicates a potentially hazardous 
situation, which, if not avoided, can result in 
personal injury or damage to the equipment.
This symbol indicates a potentially hazardous 
situation, which, if not avoided, may be a  
shock hazard.
This symbol indicates an imminently hazardous 
situation, which, if not avoided, could result in 
death or serious injury.
2.0  PRE-INSTALLATION
2.1  Initially, inspect the heater for possible 
damage due to shipping and handling. Claims 
for shipping damages shall be placed with the 
carrier.
2.2  Check the heater nameplate to ensure that 
the heater area classication and temperature 
code are suitable for the hazardous area 
classication.  For  details  of  hazardous 
locations with potential for explosion, refer 
to the Canadian Electrical Code or National  
Electrical Code.
2.3  Check to ensure that the heater voltage is the 
same as the supply voltage.
2.4  The  heater  must  be  installed  by  qualied 
personnel in strict compliance with national 
and local electrical codes.
WARNING
DO NOT CONNECT THE HEATER TO AN 
ELECTRICAL SUPPLY VOLTAGE OTHER 
THAN THAT SHOWN ON THE PRODUCT 
NAMEPLATE.
3.0  INSTALLATION - GENERAL REQUIREMENTS
3.1  Norseman
TM
 XB heaters are approved for wall 
or oor mounting with the terminal housing at 
the bottom. Ensure that is the wall sufciently 
strong to support the heater which, depending 
on the model, could weigh up to 100 lbs (45 
kg). Otherwise use the brackets supplied to 
stand the heater on the oor.
3.2  Do not recess the Norseman
TM
 XB heater 
into the wall. Use of the brackets supplied will 
ensure that the minimum spacing from the 
wall of 3.75” (95 mm) is maintained.
3.3  If more than one heater is being installed, 
maintain at least 3” (76 mm) between adjacent 
heater extrusions. NEVER INSTALL ONE 
HEATER ABOVE THE OTHER.
3.4  The Norseman
TM
 XB heater relies on natural 
convection and “black heat” radiation to transfer 
heat to the surroundings. Try to maintain a 12” 
(300 mm) clearance and NEVER LESS THAN 
6” (150 mm) clearance in front of and at the 
sides of the heater.
3.5  Use guard rails in front of the heater if there 
is a possibility that moving equipment could 
come in contact with the heater.
TYPE XB EXPLOSION-PROOF 
CONVECTION PANEL HEATER
INSTALLATION, OPERATION & 
MAINTENANCE INSTRUCTIONS
E-mail: info@ccithermal.com  www.ccithermal.com
Date of Issue: November 2013 
10457.Rev.2.01
Printed In Canada
C US
®
CAUTION
CAUTION
WARNING
POCC CA. ГБ06.B00913
ISO 9001