- Kitchen Appliance Manufacturer Ventilation Hood User Manual

8
Mounting your extractor
6. When used with a CDA hob, the extractor is required
to be 650mm above the hotplates. Measure the height
of the ceiling and then the hotplate height from the floor.
The length of the support sections should be calculated
as follows: -
Length of support = Ceiling height – (149 + 650 + Hotplate
height)
Note that if the exact height cannot be set, use the
frame position corresponding to the next highest one.
7. Fit the lower section (B) to the upper section (C) at the
correct height and secure in position using the supplied
screws (G)
8. Refit (If required) and secure the motor body to the
lower section and secure with the supplied screws.
Fig. 10
Fig. 11