ECHK90 & ECPK90 Extractors Manual for Installation, Use and Maintenance Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.
Important The CDA Group Ltd cannot be held responsible for injuries or losses caused by incorrect use or installation of this product. Please note that CDA reserve the right to invalidate the guarantee supplied with this product following incorrect installation or misuse of the appliance or use in a commercial environment.
safety (LVD) and Electromagnetic interference compatibility (EMC). IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE 2002/96/EC. At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer providing appliance recycling services. Disposing of a household appliance separately avoids possible negative consequences for the environment and health.
• This extractor has been designed to be used in a room with a volume of less than 36m3. • Steam cleaners must not be used when cleaning this appliance. • The performance of your extractor will vary depending on a number of factors. These include: type of extraction, length of ducting, room volume, ventilation available and cleanliness of the filters.
Using your Extractor For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately 15 minutes after the end of cooking. Fig. 1 A B C Control Panel A - Power off button B - Speed level buttons C - Light button To switch the extractor light on or off • Press button “C”.
Care and Maintenance IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. Cleaning You should use a non-abrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean you extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth, for example the CDA E-Cloth.
position to prevent damage from other items in the dishwasher. After rinsing and drying, replace the filters. To remove the grease filters, pull open the handle on the grease filter. It will release at the handle side. Then lower the grease filter to remove it completely. To replace the grease filter, repeat the steps in reverse. Please note: Cleaning the grease filters in the dishwasher may lead to discolouration. This is normal and does not constitute a fault with the appliance.
Changing the Light IMPORTANT: DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Carefully prise open the lamp assembly cover (D) using a small, flat-bladed screwdriver and remove the old bulb (C).
Bulb replacement is not covered by the guarantee. Only use bulbs recommended for your extractor. Do not fit bulbs of a higher power rating. Bulbs of a lower power rating may be adequate for use, generally last longer and use less energy. Mounting your Extractor ceiling When the extractor is to be installed above an electric hob, the minimum distance between the hob and extractor must exceed 600mm (650mm is recommended).
your hob being disconnected from the gas supply and the installation being reported to RIDDOR (The height should be measured from the top of the burners). IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB, THE MINIMUM DISTANCE BETWEEN THE HOB AND EXTRACTOR MUST BE AT LEAST 760mm. The width of any hob must not be greater than the width of the extractor installed above it. Ducting and Ventilation For best performance and lowest noise output, we recommend the use of 120mm ducting.
Installation Note • We recommend that you seek the help of another individual when installing this product. • The fixings supplied are suitable for most installations. It is the responsibility of the installer to ensure that the fixings are suitable for the ceiling type in the property. Installation 1. Firstly, fix the vent outlet to the extractor body using four screws, as shown in fig 5. Fig. 5 Fig. 6 4 3 2 1 2.
calculation shown below for your extractor (refer to fig 4): A = Height of gas hob burner or electric hotplate height from the kitchen floor B = Clearance required: Gas hobs 750mm recommended Electric hobs: 650mm recommended Fig. 8 A+B is the required height of the body of the extractor above the floor. Next we need to calculate the required height of the extractor. Whole extractor height = ceiling height height above floor (A+B). 4.
be at least the minimum height specified) 5. Place the chimney section over the body assembly, as shown in fig 8. 6. With the help of another individual, raise the whole assembly to the ceiling and fix securely in place using four screws appropriate for the wall plugs inserted in step 2. Ensure that the supporting ceiling is strong enough to take the weight before releasing the extractor. 7.
Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.
NOTE: USE A 3A FUSE Assembly and electrical connection should be carried out by competent personnel. When installing this product we recommend you seek the help of another individual. Do not mount the isolation switch behind the chimney section. It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation.
Troubleshooting If your extractor is not working: 1. Check that the mains supply has not been switched off. 2. Check that the fuse in the spur has not blown. Contact CDA Customer Care A: Customer Care Department, The CDA Group Ltd, Harby Road, Langar, Nottinghamshire, NG13 9HY T: 01949 862 012 F: 01949 862 003 E: service@cda.eu W: www.cda.
Energy Efficiency Information Attribute Model Identification Annual Energy Consumption Time increase factor Fluid Dynamic Efficiency Energy Efficiency Index Measured airflow at Best Efficiency Point Measured Pressure at Best Efficiency Point Maximum airflow Measured electric power at Best Efficiency Point Nominal lighting power Average illumination of the lighting system on the cooking surface Measured power consumption in standby Measured power consumption off mode Sound power level Grease Filter Efficienc
Please contact our Customer Care Department, or for Service on the details below. Customer Care Department • The Group Ltd. • Harby Road • Langar • Nottinghamshire • NG13 9HY T : 01949 862 012 F : 01949 862 003 E : customer.care@cda.eu W : www.cda.