Integration of the SIMATIC MV420 in the automation environment
■
Technical specifications
SIMATIC connection
Field level
Control level
Management level
Connection to PC
HMI
G_FS10_XX_00356
Enterprise Resource
Planning (ERP)
RS232/
RS422
RF620R RF640R
RF180C/
RF182C
(TCP/IP)
MV440MV440 MV440 MV440
ASM 456
Industrial Ethernet
Ethernet
Industrial Ethernet
PROFINET/
Industrial Ethernet
PROFIBUS
S7-300
Manufacturing Execution
Systems (MES)
MV420MV420
RFID Middleware
RF340R
SCALANCE
X108PoE
Order No. 6GF3 420-0AA20 6GF3 420-0AA40
Product-type designation MV420 SR-B code reader MV420 SR-P code reader
Suitability for installation
1D codes: Int. 2/5, Code 128, Code 39, EAN 13,
EAN 8, UPC-A, UPC-E, GS1,
2D codes: DMC, PDF417
(without: Truncated, Micro and Macro),
QR (without: Micro and Macro), Vericode
1D codes: Int. 2/5, Code 128, Code 39, EAN 13,
EAN 8, UPC-A, UPC-E, GS1,
2D codes: DMC, PDF417
(without: Truncated, Micro and Macro),
QR (without: Micro and Macro), Vericode
Interfaces
Design of the electrical connection the Industrial
Ethernet Interface
M12, d-coded M12, d-coded
Design of the electrical connection of the
PROFIBUS interface
- -
Design of electrical connection of RS 422 interface
M16, 12-pin M16, 12-pin
Design of electrical connection of RS 232 interface M16, 12-pin M16, 12-pin
Design of electrical connection for supply voltage
M16, 12-pin M16, 12-pin
Design of electrical connection at the digital
inputs/outputs
M16, 12-pin M16, 12-pin
Number of digital inputs 1 1
Number of digital outputs
3 3
Design of digital inputs One high-speed trigger input One high-speed trigger input
Design of digital outputs
• 2 isolated outputs 50 mA,
• 1 high-speed trigger input for external lighting
• 2 isolated outputs 50 mA,
• 1 high-speed trigger input for external lighting