Operating instructions
Code reading systems
Stationary code reading systems
Introduction
5/7
Siemens ID 10 · 2014
5
■
Integration
The SIMATIC MV420/440 code readers have industry-standard
PROFINET and communication module interfaces on the device.
In addition, communications interfaces such as Ethernet and
RS232 are directly available on the device.
Via the specified interfaces, the following communication
services can be used:
Via the communication module interface, all communication
modules can be used, e.g. for the PROFIBUS connection. The
communication module interface is compatible with all available
communication modules both electrically and with regard to pro-
tocol. Connection via a communication module makes it easy to
switch between optical code reading with SIMATIC MV420/440
and RFID readers, simply by reconnection. The PLC program-
ming is performed with the aid of function blocks that are avail-
able for SIMATIC and SIMOTION.
The advantage of connecting SIMATIC MV420/440 to a commu-
nication module is that a uniform programming interface is avail-
able for a wide variety of PLC types and fieldbus systems. In ad-
dition, the complete cable portfolio for the communication
module interface is available.
At the same time as being connected via a communication mod-
ule to the process (transmission of read result), the PROFINET
interface on the device can also be used for a separate interface
to HMI or a control desk.
Integration of SIMATIC MV420/MV440 by means of the SIMATIC RF180C communication module
Usable communication services Interface
PROFINET IO (FB79)
Onboard MV440 PROFINET
interface.
PROFINET IO (FB101, Ident profile) Onboard MV440 PROFINET
interface.
PROFINET IO (FB45, FB101,
Ident profile)
Via communication module interface
using the RF180C communication
module
PROFIBUS DP V0/1 (FB45,
Ident profile)
Via communication module interface
using the ASM 456 communication
module
TCP/IP native
Onboard MV440 PROFINET
interface.
RS-232 (ASCII)
Onboard MV440 RS232 interface.
SIMATIC
connection
Field level
Control level
Management level
Connection to PC and third-party
controllers
Data,
trigger,
power supply
Industrial Ethernet
(optional):
Startup,
image transfer
DI/O:
e.g. for external trigger
per proximity switch
1)
Programming with standard function block FB45
2)
Programming with PIB standard block according to IEC61131
PLC
G_FS10_XX_00365
Enterprise Resource
Planning (ERP)
HMI
MV440
RF340R
RF180C
Industrial Ethernet
Ethernet
PROFINET
2)
Industrial
Ethernet
PROFINET
1)
Manufacturing Execution
Systems (MES)
MV420