Operating instructions
3-18  Installation 
Mounting 
Nordson 
Sensors 
(continued) 
3. Locate the sensor bracket so that the sensor Is no closer than 2 in. 
(5.1 em) nor further than 15 in. (38.1  em) from the substrate. 
4. Securely connect the sensor bracket to the mounting surface. 
Excessive movement 
or 
vibration can result 
in 
intermittent 
or 
false 
operation caused 
by 
loss 
of 
alignment to the substrate. 
5. Using the two mounting bolts provided with the sensor bracket, 
secure the sensor to the bracket (Figure 3.13). 
Figure 3.13 - Connecting the sensor 
and 
bracket 
1 -
114 
mounting bolts (2 supplied) 
2 - Bracket 
3 
-Lens 
centerline, 1. 12 in. (28.5 mm) 
4 
-Front 
of 
sensor tilts vertically 
+I-
15 
degrees from horizontal 
PIN 
108 
38!1A 
57
·U 
I/SI3 
6. Route the sensor leads through water-tight conduit (for an IP-54 
enclosure rating} and the strain relief connector and into the PC40. 
7. Skip 
to 
"Nordson Photosensor Wiring Connections." 