Operating instructions
4. 
Guns 
Not 
Firing {continued) 
Problem 
PC40 
trigger 
input 
LED(s) dark. 
PC40 
output 
LED(s) 
dark. 
C  NordSon Corporation 1
993 
AI 
Aogtu 
R$$"""0<1 
Possible Reason 
Sensors not mounted within 
operating range. 
Sensor misaligned. 
Dirty sensor 
lenses and/or 
retroreflector. 
Damaged sensor wires. 
Incorrect 
or 
missing wire 
connections. 
Sensor 
failure. 
PC40 failure. 
Sensor or sensor wiring problem. 
Wrong memory selected. 
Channel not configured. 
Channel not activated. 
PC40 failure. 
Troubleshooting  5-3 
Corrective Action 
Mount within proper range. 
Check; 
align 
if 
necessary. 
Clean lenses and/or retroreflector. 
Inspect and replace 
or 
repair as 
necessary. 
Turn power to 
PC40 OFF; 
remove front assembly and check 
connections. 
Replace; contact your Nordson 
representative. 
Replace; contact your Nordson 
representative. 
Check if PC40 input LEOs also 
dark; if so, 
go 
to "PC40 trigger 
input LEOs dark," 
earlier in this 
section. 
Select the correct memory. 
Configure channel. 
Activate channel. 
Replace; contact your Nordson 
representative. 
Refer to 
Figure 
5.1 
Sec. 4, 
"Programming 
Memory." 
Sec. 4, 
"Selecting 
Available 
Parameters: 
Sec. 4, 
"Programming 
Channel." 
PIN 1
08 
389A 
57-28  1/93 