Technical data
40
Table for the Choice of the Injectors
GB
Cat: II 2H3+
Burners
Nominal
Power
kW
Reduced
Power
kW
G30 - 28-30 mbar
G31 - 37 mbar
G20 - 20 mbar
Ø Injector
1/100 mm
Tube ring
opening
[mm]
Ø Injector
1/100 mm
Tube ring
opening
[mm]
Auxiliary (A) 1,00 0,30 50 - 72 (X) -
Semi-Rapid (SR) 1,75 0,45 65 - 97 (Z) -
Rapid (R) 3,00 0,75 85 - 115 (Y) -
Triple Ring (TR) 3,50 1,50 95 - 135 (T) -
Oven (left)
3,70 0,75 92 fully open 140 5
Grill (left)
2,50 - 80 fully open 120 4
Oven (right)
2,20 0,63 72 fully open 110 4
Grill (right)
2,00 - 70 fully open 105 2
Increase of Air Necessary for Gas Combustion (2 m
3
/h x kW)
Burners Air necessary for combustion (m
3
/h)
Auxiliary (A) 2,00
Semi-Rapid (SR) 3,50
Rapid (R) 6,00
Triple Ring (TR) 7,00
Oven (left) 7,40
Grill (left) 5,00
Oven (right) 4,40
Grill (right) 4,00
Lubrication of the Gas Taps
The operations must be executed by a qualied technician.
IMPORTANT: All intervention regarding installation maintenance and conversion of the appliance must
be fullled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this obligation.