Specifications

31
Regulation of Air Supply to Oven and Grill Burners
To regulate the air supply it is necessary to remove the burners from their housings (gs. 39 - 41).
Using a cross-head screwdriver, slacken the screws A securing the air ow regulation collar B
(g. 42) and move the collar forward or backward to increase or reduce the air aperture in accor-
dance with gas type and the indications in the Table for the choice of the injectors’.
IMPORTANT: If the air ow regulation collar B is not already tted on the burner (e.g. oven burner
set in the factory for LPG use), it is supplied with the kit for the gas conversion. In this case the air
ow regulation collar B shall be tted as indicated in gure 42:
the collar B shall be folded around the burner (one half part at the top and one half part at
the bottom);
the throttled section shall be oriented toward the burner deector (opposite side with re-
spect to the injector).
Replace and light the burners to check the ames.
1 2
A
B
B
Fig. 42
Grill burner
Oven burner
Ring opening [mm]
(see the Table for the choice
of the
injectors”)