Installation Instructions
v5-0919
A certiîżed electrician must install wiring and wire motor control.
Be sure to follow all electrical codes for your area.
WARNING:
PRIEFERT MANUFACTURING RECOMMENDS THAT ALL WIRE BE RUN THROUGH
ELECTRICAL GRADE CONDUIT TO PREVENT INJURY OR DEATH DUE TO ELECTROCUTION HAZARD
AND/OR DAMAGE TO EQUIPMENT.
Horse Walker Electrical Instructions (cont.)
CONTROL PANEL DESCRIPTIONS FROM PREVIOUS PAGE
1. 24v Power Supply
(Touch Screen Control Panel Only)
2. PLC
3. Motor Starter Relay
4. Line Reactor
5. Braking Resistor
6. 10 Amp Fuse
7. Motor Drive VDF
8. VDF Power Unit
9. Remote Receiver
10. Incoming Power (
See diagram above)
30amp double pole breaker from Main Power Supply - Four(4) #10 Wires
L1 Black - Hot; L2 Red - Hot; N White - Neutral; G Green - Ground
11. Outgoing Power To Charger (
See diagram above)
to Walker - Three(3) #12 Wires
L1 Black - Hot; N White - Neutral; G Green - Ground
12. Outgoing Power To Walker Motor (
See diagram above)
to Walker - Four(4) #10 Wires
T1 Black - Hot; T2 Red - Hot; T3 Blue - Hot; G Green - Ground
12
Basic Wiring Diagram
MAIN POWER SUPPLY
TO CONTROL BOX
Four(4) #10 Wires
Black - Hot
Red - Hot
White - Neutral
Green - Ground
TO WALKER MOTOR
Four(4) #10 Wires
T1 - Black
T2 - Red
T3 - Blue
T4 - Green
TO FENCE CHARGER
Three(3) #12 Wires
G - Green
N - White
L1 - Black
SHOULD HAVE 11 WIRES
AT CONTROL BOX
Four(4) #10 Wires IN
Four(4) #10 Wires OUT
Three(3) #12 Wires OUT
MAIN
POWER
SUPPLY
CONTROL BOX
WALKER /
WALKER BASE