GATE DELAY
Located on the back of the Control Box is a “GATE DELAY” setting. A
silver knob activates and sets the delay timing. Each click clockwise
gradually delays the activation of the opening of the Front Gate from
2 to 30 seconds.
The rider can adjust the amount of time for the chute to open after
pressing button “1”, and then ready for the steer release.
AUTOMATIC
The button on the right rear of the Control Box switches the chute
into “AUTOMATIC” mode, where the chute uses an electronic eye to
detect the presence or absence of a steer.
In Automatic mode, pressing button “1” opens the Front Gate.
A few seconds after detecting the steer left the chute, the
headgate closes. The tailgate then opens, and upon detection
of the next steer having entered the chute, the tailgate closes.
One push of a button has completed the entire cycle & ropers have
the next steer loaded and ready to go upon return to the roping box.
AUTOMATIC with GATE DELAY
Both of these features, used together, allows the rider to choose a
Delay period from when the Front Gate opens, and the opening of the
Neck Gate. Pressing button “1” opens the Front Gate, seconds later,
the Neck Gate opens. The chute then cycles again as in “Automatic”
mode. Pressing button “3” will then close the Neck Gate.
Combining these functions will help train your horse to respond to
the que from the rider, NOT the opening of the chute.
The Upper buttons of the Remote operate
the Front Gate of the Score Chute
The Lower buttons Toggle the Neck Gate
and Rear Gate of the Score Chute
Pressing this button will OPEN the
FRONT GATE of the Score Chute
Pressing this button will CLOSE the
FRONT GATE of the Score Chute
Pressing this button will toggle to
OPEN and CLOSE the
NECK GATE of the Score Chute
Pressing this button will toggle to
OPEN and CLOSE the
REAR GATE of the Score Chute
GATE DELAY “ON” & set to 4 sec.
AUTOMATIC “ON”
AUTOMATIC with GATE DELAY “ON”
and set to 4 Seconds
Delay & Automatic Settings
Score Chute Operation
FCC Compliance Statement: This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.