Service manual

CEBORA S.p.A. 9
Check the wiring between CN2 power board (29) and CN2 panel board (26).
Disconnect temporarily, with power source off, connector CN2 on panel board
(26) and verify terminals 1 and 2 of CN2 on panel board (26) are not in short
circuit. If the case, replace panel board (26), and verify, powering the power
source with connector CN2 disconnected, the presence of 5 Vdc on terminals 1
and 2 of connector CN2 remained free. If lacking replace also power board (29).
Replace panel (26) and or power (29) boards.
3.3.2 - Power source powered, fan (16) stopped.
FAN (16) TEST.
Correct?
Fast-on terminals fan (16) = 230 Vac approximately, with switch (6) closed.
NO
YES
Make sure that there are no mechanical impediments blocking the fan.
Replace the fan (16).
Check the wiring between the fan (16) and switch (6).
Check the mains voltage conditions.
Replace the switch (6).
3.3.3 - Power source powered, display and signals does not indicate the correct values.
LAMP-TEST.
Correct?
Panel board (26), all leds lit for 1 second, after the switch (6) is closed.
YES
NO
Check the wiring between the CN2 power board (29) and CN2 panel board (26).
Check the power source supply, par. 3.3.1.
Replace panel (26) and/or power (29) boards.
ERROR CODE TEST.
Correct?
Upon start-up, after the lamp-test, yellow led (G) = lit.
NO
YES
See par. 3.4, Error code.
Check the power source supply, par. 3.3.1.
Replace panel (26) and/or power (29) boards.
3.302.212 12/01/06