BREW CENTER COFFEE BREWING SYSTEMS MODEL #'s_____ Singles Twins BC301 BC302 BC1 BC2 BC120 BC240 OPERATION MANUAL Specifications Installation & Operating Instructions Adjustments Care & Maintenance Wiring Diagram Replacement Parts List SPECIFICATIONS CAPACITY: Cups/Brew Cycle Cups/Hour ELECTRICAL DATA: Volts Watts Amps DIMENSIONS (Inches) Height* Width Depth Ship Weight (Ibs.
INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any voltage other than voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the sleeve carton off the Brewer.
approximately 20 minutes for the brewer to reach full brewing temperature (197°-203°). When the GREEN READY LIGHT comes ON the brewer is ready to brew the next batch of coffee. NOTE: Before proceeding further, make sure the sample filter pack has been removed from the funnel. CHECKING BREW CYCLE OUTPUTS. The BC-Series brewers are factory preset to deliver the proper amount of brewing water for the 12 cup, 24 cup and 36 cup brew cycles.
COFFEE BREWING INSTRUCTIONS Place filter paper into brew basket and add recommended amounts of finely ground coffee as per chart below: #CUPS BREWED RECOMMENDED COFFEE AMOUNT TOTAL BREW TIME BC1 36 Cups 6 oz. 6.0 Minutes BC2 36 Cups 6 oz. 6.0 Minutes BC120 12 Cups 2oz. 3.0 Minutes BC240 24 Cups 4 oz. 4.5 Minutes BC301 and BC302 12 Cups 24 Cups 36 Cups 2oz. 4 oz. 6 oz. 3.0 Minutes 4.5 Minutes 6.
6. To get more BY-PASS, turn slotted adjustment screw in spray-head adjuster (Item 49 in parts list) counterclockwise. Turning adjuster screw clockwise will decrease the BY-PASS flow. SPRAY-HEAD ADJUSTER Left (K245A) Right (K244A) BC 2, BC302 (K253A) BC1, BC301 FIGURE 2 The BC310 and BC302 units do not use a BY-PASS for 12 and 24 cup brewing. The BY-PASS valve is activated only when the 36 cup cycle is selected. The BC210 and BC240 models only brew 12 or 24 cups and therefore do not use a BYPASS.
2. To LOWER water temperature, simply turn knob one notch counter-clockwise to next lower number on dial. HINT: To measure water temperature accurately, remove the spray-head for a solid water stream. SOLID STATE WATER LEVEL CONTROL AND PROBE WATER LEVEL CONTROL OPERATION Components involved: 1. Solid state water level control board Part #L398A 2. Water inlet valve Pan # L397A 3. Water level probe Part #K213A 4.
HI-LEVEL FLOAT SWITCH The float switch acts as a guardian for the solid state level control and its probe. If they malfunction and cause the water inside the tank to rise, the float switch will prevent flooding by terminating the power to the solid state control board and the water inlet valve. PROBE TEST (Figure 5) If lack of water conditions remain the same, check the probe as follows: Turn on the power to the brewer. Check inside the heating tank to make sure the water is not touching the probe.
PROBLEM; WATER WILL NOT "STOP" FLOWING INTO THE HEATING TANK Follow the same procedure as above but in reverse order. Check the Water Level Probe, Solenoid and level controls. WATER INLET VALVE TEST (FIGURE 7) Turn off all power to the brewer. Observe the water level inside the heating tank. If it rises, the water inlet valve is leaking. Rebuild using Valve kit #99371 or replace inlet valve.
CARRIER Fig.
BC1, BC120, BC240, BC301 PARTS LIST FIG. # DESCRIPTION PART# FIG .
BC2 AND BC302 PARTS LIST FIG. # DESCRIPTION PART# FIG.
CARE AND MAINTENANCE INSTRUCTIONS DRAINING OF WATER TANK: Fast draining of tank is possible by Drain Hose which is located behind the front panel and held in place by a clamp to the side wall. When draining of tank is required, always disconnect power supply and turn thermostat counterclockwise to the OFF position. CLEANING; 1. Wipe all exterior surfaces of the unit with a soft, damp cloth using warm water and mild detergent.