SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. Volts Watts BC301-IT BC2-IT BC302-IT 120/230 4100 120/230 6200 120/230 6200 Amps 18 27 27 Wall Outlet (Receptacle) 6-30R 6-30R 6-30R Power Cord CE202 – 30A optional All Brew Centers are single phase with 3 wires plus a ground with cord and plug, except Eport 220V, 1 PH, (UROPEAN). MECHANICAL SPECIFICATIONS MODEL NO. BC301-IT (in) BC2-IT (in) BC302-IT (in) 3.1 6.2 6.
FEATURES AND BENEFITS OF THE DIGITAL, MEMBRANE CONTROL TOUCH PAD BREWER 1. 100% Solid State Control for improved reliability. 2. Modular design and reduced component count for ease of service. 3. Optional Low Water Temperature Lockout to prevent dispensing at water temperatures below an adjustable threshold. 4. Redundant system interlocks for uncompromising user safety. 5. Large two line display for viewing system status on digital display and modifying parameters. 6.
INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer.
PROGRAMMING INSTRUCTIONS TO ACCESS PROGRAMMING – Press Simultaneously Both Buttons TO SCROLL THRU PROGRAMMING FUNCTIONS – Press One Button TO CHANGE OR RESET PARAMETER VALUES LED LIGHTS BREW BUTTONS WARMER BUTTON POWER BUTTON CANCEL LAST OPERATION The following is a Functional Description of the Single Station Brewer: Modes of Operation - Overview Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset.
MODES OF OPERATION – DESCRIPTIONS Initialization Mode: The following screen signifies the presence of this mode: CECILWARE &&&&& REV #.# Description – This mode is active only during the first few seconds after “power-on”. The purpose of the Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision Number (depicted by “#.#”).
Description – The Brew Fill Constant Calibration State is entered from the Heating State or the Ready State by simultaneously pressing the [Down Arrow] Key and the Brew Key. The system will immediately energize the Dump Solenoid (and dispense hot water) for exactly 10 seconds. The required Brew Fill Constant can be verified by dividing the volume of hot water dispensed by 10 thus yielding the actual Brew Fill Constant in ounces per second.
SERVICE MODE Description – The main function of Service Mode is to give qualified personnel the ability to configure the system to meet the requirements of each installation. General Conventions (unless otherwise indicated) 1) 2) 3) 4) 5) 6) To enter or exit Service Mode simultaneously depress both the hidden key under the Cecilware Logo (CW Key) and the hidden key under the first letter of the Model Name (MN Key) until the buzzer sounds (approximately two seconds).
SOAK TIME SOAK TIME ## SECONDS Description – The Soak Time is the amount of time that the system will wait between the end of the hot water infusion period and the beginning of brewing. PULSE BREW PULSE BREW ON/OFF Description – The Pulse Brew feature gives the user the ability to brew by non-continuously dispensing (pulsing) hot water. PULSE ON TIME PULSE ON TIME ## SECONDS Description – The Pulse ON Time is the amount of time that the system will continuously dispense hot water during a Brew Cycle.
SLEEP TIMER SLEEP TIMER ON/OFF Description – The Sleep Timer feature automatically reduces the water temperature to three degrees above the Lockout Temperature if the machine has not started a Brew Cycle within two hours. WARMER POWER WARMER POWER ### % Description – The Warmer Power feature allows the user to reduce the actual heating power of the warmers. The percentage displayed is percentage of maximum power.
ADJUST SECONDS ADJUST SECONDS DAY HH:MM:## Description – The Adjust Seconds function allows the user to adjust (set) the systems Real-Time-Clock Seconds placeholder. ADJUST MINUTES ADJUST MINUTES DAY HH:##:SS Description – The Adjust Minutes function allows the user to adjust (set) the systems Real-Time-Clock Minutes placeholder. ADJUST HOURS ADJUST HOURS DAY ##:MM:SS Description – The Adjust Hours function allows the user to adjust (set) the systems Real-Time-Clock Hours placeholder.
ERROR MODE Description – The main function of Error Mode is report any system malfunctions and to disable the unit The system must be “powered down” using the Power Key located on the membrane keypad to reset any reported error KEYPAD ! SYSTEM ERROR ! KEYPAD Description – This screen is displayed and the unit is disabled when a key-press is detected during the initial application of power to the system. This test is not performed during a Power Key initiated “poweron” sequence.
TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1. No power to the machine. a) Loose wire connection. b) Inoperative Power Safety Relay c) Blown fuse. a) Check wire connections to Relay. See Power Safety Relay Test.
SPECIAL COMPONENTS TEST AND ADJUSTMENTS 1) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin) Turn power off from touchpad. If the water level rises inside the tank, and shoots out of the overflow, the Water Inlet Valve is leaking. Disconnect wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this test a few times. The problem may be in the Probe.
5) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain The Water Tank To Just Below The Level Of The Dispense Valves. Remove The Valves And Clean. You Can Take These Valves Apart By Hand As Shown. Replace The Assembly As Needed. Replace The Valve Into The Tank And Refill tank. a) The SINGLE DISPENSE VALVE is factory adjusted to dispense 0.5 oz./sec. of water during the brew cycle (spray duration). b) The DOUBLE/ DILUTION DISPENSE VALVE is factory adjusted, on both sides, to dispense 0.
BC2-IT OPEN FRONT VIEW 6 7 8 9 10 11 12 PARTS IDENTIFICATION BC2-IT BC302-IT QTY P/N QTY BC2-IT, BC302-IT BACK VIEW BC301-IT ITEM P/N 1 2 SF26A ---NG35A NG37A 1 -1 1 3 4 5 6 DO42A SF28A SF27A V210Q 1 1 1 1 7 8 9 10 11 12 SF74Q R615A G108A M090A U485A M172S 1 1 1 2 1 1 DESCRIPTION SB49A 1 Cabinet Top Cover ---- Touch Pad Label: NG39A 1 BC1-IT /BC2-IT NG40A 1 BC301-IT / BC302-IT NG36A 1 BC120-IT D042A 2 Faucet, Hot Water SB66A 1 Front Cover SB65Q 1 Cabinet Frame Ass'y V210Q 2 Funnel Ass'y, Bla
TOP CABIN OPEN VIEW BC302-IT 1 21 2 20 3 19 4 18 5 17 6 16 7 15 8 14 13 9 12 10 11 TOP CABIN - PARTS IDENTIFICATION ITEM P/N BC301-IT QTY 1 2 3 4 5 6 7 8 9 10 11 12 L069A L656A L639A K402Q L688B L689A CH87A L553A B203A L669A M483A K671Q M197A SD06Q E107A K668A M483A M483A K683A M483A K525A P465A G402A -------G286A RK70A 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 L069A L656A L639A K402Q L688B L689A CH87A L553A B203A L669A M483A K671Q M197A SD06Q E107A K668A M483A M483A K683A M483A K
TOP CABIN OPEN VIEW BC301-IT BOTTOM CABIN OPEN VIEW BC301-IT BC2-IT, BC302-IT 1 6 5 2 4 3 5 6 3 4 OTTOM CABIN - PARTS IDENTIFICATION ITEM P/N BC301-IT QTY 1 2 3 4 5 6 L623A L069A CD257 B083A CE202 C396Q 1 1 1 1 1 1 P/N BC2-IT QTY BC302-IT L623A L069A CD257 B083A CE202 C396Q 2 1 1 1 1 1 DESCRIPTION TRIAC, 40 Amps POWER SWITCH (located in the back at bottom or at the top ) WATER INLET VALVE (mounted on back panel or inside bottom compartment) TERMINAL BLOCK POWER CORD FUSE HOLDER ASS’Y
CARRIER ASS’Y 1 2 3 4 5 6 7 14 CARRIER ASS’Y 97208 Item 1 2 2 3 4 5 6 7 8 9 10 11 12 13 14 13 [* RECOMMENDED SPARE PARTS] Description Part # * Handle, black 3” 02015 * Hold Down Bracket U833A * Thumb Screw M299A * Carrier Cover S.S.
FRONT VIEW-BC301-IT BACK VIEW- BC2-IT, BC302-IT 20