ELECTRICAL SPECIFICATIONS Amps Kilowatts 3 1 Heater Heater 1 Phase 3 Phase Phase Element Phase Element (3) wire (4) wire Model No. Volts FE75-N CL75-N CH75-N 120/240 7 G031A (1) 6 G024A (1) 29 15 120/208 5.3 G031A (1) 4.5 G024A (1) 26 12 120/240 8 G013A (1) 8 G026A (1) 34 20 120/208 6 G013A (1) 6 G026A (1) 29 17 120/240 7 G031A (1) 8 G026A (1) 29 20 120/208 5.3 G031A (1) 6 G026A (1) 26 17 220 6.
POWER STOP BREW 29.1 19.3 BLEND 9 8 OF F 10 7 6 1 5 4 3 2 CAUTION HOT SURFACES 3.5 2.5 10.1 NN10A 4.0 16.0 5.4 14.0 POWER STOP BREW BLEND 29.1 19.3 9 8 OF F 10 7 6 1 5 4 3 2 CAUTION HOT SURFACES 3.5 NN10A 2.5 10.1 4.0 28.0 5.4 14.
POWER STOP BLEND BREW 31.2 9 8 OF F 10 1/2 BREW 7 6 1 5 4 3 2 21.2 CAUTION HOT SURFACES 3.5 2.5 10.1 NN10A 4.0 32.0 5.4 16.0 POWER STOP BREW 34.5 BLEND 9 8 OF F 10 7 6 1 5 4 3 2 23.4 CAUTION HOT SURFACES 3.5 NN10A 2.5 9.1 4.0 36.1 5.4 18.
** UNPACKING AND INSPECTION ** UNPACKING INSTRUCTIONS: Carefully unpack urn and inspect immediately for shipping damage. Your automatic coffee urn was shipped in a carton designed to give it maximum protection in normal handling. It was thoroughly inspected before leaving the factory and the carrier accepted and signed for it. File any claims for shipping damage or irregularities directly with the carrier, not with the company.
PARTS LIST - FE-N SERIES AUTOMATIC COFFEE URNS ITEM PART # DESCRIPTION QUANTITY FE75-N FE75-N DUAL BREW CL75-N CH75-N 1 1 1 1 FE100-N FE100-N CL100-N CH100-N FE200-N CL200-N DUAL DUAL BREW BREW 1 1 1 1 1 1 FE300-N 1 B157A TERMINAL BLOCK 4 WIRE 2 C036A CONTACTOR, 3 POLE, 50 AMP - (240V) 1 2 CG12A CONTACTOR, 3 POLE, 50 AMP - 120V 1 1 1 1 1 1 1 1 1 1 1 3 C395A FUSE 6A SC-6 1 1 1 1 1 1 1 1 1 1 1 4 C396A FUSEHOLDER, SC-6 1 1 1 1 1 1 1 1 1 1 1 5 C
SOLID-STATE TIMER ADJUSTMENT: A factory pre-set electronic solid-state timer controls the volume of water for each brew cycle. If more or less water is desired, follow these instructions: Turn knob of timer clockwise to increase volume of water or counterclockwise to decrease it. Run through a complete brew cycle after each adjustment. Since timer cannot be readjusted in mid-cycle, simply push cycle stop switch at bottom right of side box if water gets too high.
SPRAY ARM BY-PASS ADJUSTMENT (ALL Urns ): Adjustable bypass allows proper brew extraction even with variations caused by soft or treated water. If bypass requires adjustment to correct for local water conditions, proceed as follows: Position spray head over center of coffee liner and press BREW switch. Turn by-pass adjustment screw clockwise to decrease by-pass flow (for stronger coffee) or counter-clockwise to increase by-pass flow (for weaker coffee).
CAUTION: DISCONNECT POWER BEFORE ATTEMPTING ANY ELECTRICAL REPAIRS. IF WATER FAILS TO HEAT: 1. Check line fuse or circuit breaker. Replace or reset if necessary. 2. Make sure thermostat is in ON position. If thermostat pilot light does not come on, replace thermostat. (Refer to instructions below.) If pilot light is on, measure continuity between terminals l and 2 of thermostat, and between terminals 3 and 4. If a resistance is measured, replace thermostat. 3.
IF WATER RUNS OUT AT OVERFLOW DRAIN: 1. Make sure urn is level and overflow tube is vertical. 2. Remove fuse from rear of side box. 3. If water continues to flow, solenoid valve is dirty or not seating properly. Replace solenoid as described above. NO WATER FROM SPRAY HEAD: 1. Check fuse first. 2a. For all urns except CL's: Depress BREW switch and release. If switch remains lit, water pump is probably not operating. Lift off side box door and check if fan on water pump is rotating.
WARNING - These steps involve working with very hot water. Cleaning the Cecilware Automatic Coffee Urn.... To ensure the highest quality, best tasting coffee, your urn must be cleaned daily after the last batch. Regular cleaning and preventive maintenance is essential in keeping your coffee urn looking and working like new. CAUTION - Do not use cleansers, bleach liquids, powders or any other substance containing chlorine. These products promote corrosion and will pit the stainless steel.
FE-N SERIES W/ SINGLE TIMER GND L1 L2 AIR AGITATOR PUMP Gray DELAY TIMER Yel BLEND Wht Blue SINGLE TIMER NC Blue BREW PUMP Yel NC BREW LIGHT NO Yel Wht Wht Wht STOP Red Yel Yel BREW SWITCH WATER INLET VALVE Red WATER LEVEL CONTROL RED WHT BLU YEL WATER LEVEL PROBES 1 FILL 2 AC-1L 3 AC-2N 4 L-LEVEL 5 H-LEVEL 6 COMMON LED WATER GND THERMOSTAT CONTACTOR FUSE L2 (N FOR 120V) POWER SWITCH L1 GND FE-N SERIES WIRING DIAGRAM NE249 SH 1 OF 3
FE-N SERIES W/ DUAL TIMER L1 GND L2 Wht Wht BREW LIGHT AIR AGITATOR PUMP Purple BREW SWITCH NO Purple Gray DELAY TIMER Yel BLEND Wht Blue DUAL TIMER NC Blue BREW PUMP Yel Wht NC HALF BREW LIGHT NO Yel Wht Wht STOP Red Yel Yel HALF BREW SWITCH WATER INLET VALVE Red WATER LEVEL CONTROL RED WHT BLU YEL WATER LEVEL PROBES 1 FILL 2 AC-1L 3 AC-2N 4 L-LEVEL 5 H-LEVEL 6 COMMON LED WATER GND THERMOSTAT CONTACTOR FUSE L2 (N FOR 120V) POWER SWITCH L1 GND FE-N SERIES WIRING DIAGRAM N
TERMINAL BLOCK L1 L2 L3 N 2 3 CONTACTOR 1 TERMINAL BLOCK L1 L2 L3 N 3 GALLON - SINGLES & TWINS CONTACTOR 3 PHASE HEATER G026A (8 KW) G024A (6 KW) 1 PHASE HEATER G013A (8 KW) G031A (7 KW) TERMINAL BLOCK L1 L2 L3 N CONTACTOR 3 2 1 2 3 CONTACTOR 1 TERMINAL BLOCK L1 L2 L3 N 6 GALLON TWINS 3 PHASE HEATER 3 PHASE HEATERS G018A (5 KW EACH) 1 PHASE HEATER 1 PHASE HEATERS G011A (5 KW EACH) TERMINAL BLOCK L1 L2 L3 N 9 GALLON TWINS CONTACTOR FE-N SERIES WIRING DIAGRAM 1 PHASE HEATERS
G AIR AGITATOR PUMP L2 L1 DELAY TIMER NO BLEND 1 NC BREW PUMP 2 TIMER 1 2 BREW LIGHT WATER LEVEL CONTROL WATER INLET VALVE RED WHT BLU YEL WATER LEVEL PROBES 1 FILL 2 AC-1L 3 AC-2N 4 L-LEVEL 5 H-LEVEL 6 COMMON LED WATER GND THERMOSTAT ON-OFF CONTACTOR POWER SWITCH FUSE GND L2 (N FOR 120V) CL-N & CH-NSERIES URNS CECILWARE CORPORATION L1