INSTALLATION Water Inlet Connection: This equipment is to be installed to comply with the applicable Federal, State, or local plumbing codes having jurisdiction. In addition: 1. A quick disconnect water connection or enough extra coiled tubing (at least 2 times the depth of the unit) so that the machine can be moved for cleaning underneath. 2. An approved back flow prevention device, such as a double check valve to be installed between the machine and the water supply.
PROGRAMMING FOR AUTOMATIC DISPENSE (See Door diagram) READY LIGHT HEATING LIGHT 1. 2. 3. 4. 5. Turn Power Switch ON (toggle switch inside door). PRESS and HOLD [red] STOP Button with one hand. PRESS and HOLD [green] DISPENSE Button with other hand. RELEASE [red] STOP Button ONLY. Continue to HOLD [green] DISPENSE Button until BUZZER sounds, then RELEASE. 6. PRESS and RELEASE [green] DISPENSE Button. Product begins dispensing. When it reaches the “DESIRED VOLUME”, 7.
CLEANING AND SANITIZING: SANITIZING: All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°F - 90°F). Soak all parts for a minimum of 3 min. in the sanitizing solution. Note: Always start with an unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span.
30 25 11 24 9 17 28
WATER LEVEL 32 1 4 2 OVERFLOW 3 18 DRAIN WATER INLET
PRODUCT GUIDE CD70A WIRE AUGER CD74A (17mm DIA, 12.
PARTS LIST : JAVA 2-QB-D, -D1, -D2, -D3, -DC 1 1 2 3 4 5 6 7 8 8 9 9 10 11 12 13 14 14 15 16 17 17 18 18 19 20 21 22 22 23 24 24 25 25 26 27 27 28 29 29 30 31 32 33 34 34 34 35 36 37 HEATER, 1500W, 120V HEATER, 3500W, 240V THERMOSTAT SILICONE GROMMET, 12 mm HI-LIMIT, 200° CUTOUT PUSH BUTTON SWITCH (GREEN DISPENSE) PUSH BUTTON SWITCH (RED STOP) PUSH BUTTON SWITCH (AMBER HOT WATER) PILOT LIGHT, GREEN (READY) 120V PILOT LIGHT, GREEN (READY) 240V RELAY, 120V RELAY, 220V (FOR 240 V UNITS) POTENTIOMETER SPEED CO
TIMER SW K1 RELAY 3 5 2 4 1 3 DUAL TIMER POWER L1 K2 RELAY STOP SWITCH COFFEE 3 5 2 4 1 3 DUAL TIMER DOOR UNIT N DECAFF HOT WATER READY D.C. AUGER MOTOR . . SPEED CONTROL RINSE K2 RELAY COIL D.C.
PROGRAMMING SW. CUP/ DECANTER L1 N 3 5 2 4 1 3 DUAL TIMER POWER STOP SWITCH 3 K2 RELAY 5 K5a 2 4 1 3 DUAL TIMER DOOR UNIT K1 RELAY K5b COFFEE DECAFF HOT WATER READY D.C. AUGER MOTOR D.C. AUGER MOTOR SPEED CONTROL RINSE HOT WATER VALVE K2 RELAY COIL SPEED CONTROL DISPENSE VALVE-1 K1 RELAY COIL K4 RED WATER INLET VALVE HEATING K3 BLK WHT BLU K5 TEMP.
PROGRAMMING SW. CUP/ DECANTER K1 RELAY 3 5 2 4 1 3 DUAL TIMER POWER STOP SWITCH K2 RELAY 3 5 2 1 4 3 DUAL TIMER DECAFF HOT WATER COFFEE L1 DOOR UNIT N READY D.C. AUGER MOTOR D.C.
L1 N 3 5 2 4 1 3 TEACH ME TIMER POWER K2 RELAY STOP SWITCH COFFEE 3 5 2 4 1 3 TEACH ME TIMER DOOR UNIT K1 RELAY DECAFF HOT WATER READY D.C. AUGER MOTOR . . SPEED CONTROL RINSE K2 RELAY COIL D.C. AUGER MOTOR HEATING SPEED CONTROL DISPENSE VALVE HOT WATER VALVE K1 RELAY COIL K4 RED WATER INLET VALVE LIQUID LEVEL CONTROL K3 BLK WHT BLU WATER LEVEL PROBES YEL GRN WATER VACUUM FAN N HI-LIMIT THERMOSTAT 3 PIN CONNECTOR HEATER SW WARMER SWITCH WARMER OPTIONAL M.M.