Technical Data Bulletin

Advanced Building Products
CedAir-Mat Roof Ventilation Mats 07 72 73 - 3
B. Storage and Handling Requirements:
1. Store and handle materials in accordance with manufacturer’s instructions.
2. Keep materials in manufacturer’s original, unopened containers and packaging until
installation.
3. Store materials in clean, dry area indoors.
4. Protect materials during storage, handling, and installation to prevent damage.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Advanced Building Products, Inc., PO Box 98, Springvale, Maine
04083. Toll Free 800-252-2306. Fax 207-490-2998. Website
www.advancedbuildingproducts.com. Email info@ABP-1.com.
B. Basis of Design: CedAir-Mat, as manufactured by Advanced Building Products, Inc.
Specifier Notes: Specify if substitutions will be permitted.
C. Substitutions: [Not permitted] [Comply with Division 01].
2.2 MATERIALS
A. Roof Ventilation Mats: “CedAir-Mat”.
1. Material: Nylon 6.
2. Type: Flexible, entangled open mesh.
3. Thickness: 0.407 inch (10.35 mm).
4. Unit Weight, ASTM D 5261: 8.66 oz per sq yd.
5. Tensile Strength, ASTM D 5035 Modified:
a. Machine Direction: 100.0 lbs per sq ft.
b. Transverse Direction: 68.8 lbs per sq ft.
6. Elongation, ASTM D 5035 Modified.
a. Machine Direction: 60 percent.
b. Transverse Direction: 53 percent.
7. Fire Rating, ASTM E 84: Class A
8. Flow Rate, ASTM D 4716: 5.1 Cu.Ft./Min./Ft width
PART 3 EXECUTION
3.1 EXAMINATION
A. Examine surfaces to receive roof ventilation mats.
B. Notify Architect of conditions that would adversely affect installation or subsequent use.
C. Do not begin installation until unacceptable conditions are corrected.