User's Manual

Page 6
OPERATION
Unpack the DNS 2 carefully. Save the carton and all packing materials since you
may need them in the future. In addition to the DNS 2, the box should contain:
12V DC power supply
start-up and safety instructions sheet
warranty registration card
To maintain reliability and prolong operating life, observe the following
environmental considerations:
the temperature should be maintained between 5º and 30º Celsius
relative humidity should be in the range 30% to 80% non-condensing
strong magnetic elds should not exist nearby.
Power sources
Power is supplied by an external DC source of 8–17.5V with a lm industry 4-pin
XLR. A 12V PSU is included with the unit and this will work on any mains supply in
the range 85V to 250V, 50/60Hz AC. Connect its output to the DNS 2 power input
and then plug it into the mains supply.
Press the power on/off button to switch power on and off:
press the button briey to switch the power ON
hold the button for a couple of seconds to switch the power OFF
Controls
Each channel has its own process controls and indicators. These comprise two
illuminated push buttons, a rotary encoder with an integrated push switch, and a
small dot-matrix display. These are used for both setup and process control.
Connections
The DNS 2 offers analog and digital audio connections. It can pass its signal to
both outputs irrespective of the input used.
Select the active audio input using the two-position toggle switch on the side of the
unit. When the analog inputs are in use, a three-position switch for each channel
selects between line, microphone and microphone with +48V phantom powering.
High pass lter
An 80Hz, -18dB/oct high pass lter is available across all inputs. To toggle this for
either channel, press SETUP followed by the appropriate LEARN button. An icon
on each channel’s screen will show whether the lter is active or not.
Analog input
Set the input selector switch to ANALOG IN (switch to left).