Manual
Page 10
Individual screens - Detail mode
The rst six displays (1 - 6, viewed from left to right) show the Attenuation and Bias
information for a given channel or group on a band-by-band basis, with the lowest
frequency band shown within the furthest left display, and the highest frequency band
shown within the sixth display.
The seventh display shows the average Attenuation and Bias across all bands - i.e. the
summary display.
The eighth display shows which channel or group of channels is currently in focus.
THE ENCODERS
The encoders allow you to attenuate the detected noise and, if desired, to bias the noise
detector toward more or less noise. In Summary mode, these actions are performed
on a channel-by-channel basis. In Detail mode they are performed upon a given band
within a selected channel or group.
The focus of each encoder is indicated by a lled-in circle in its associated display, and
the process status is denoted by lled (on) or hollow (off) bar graphs.
An Attenuation or Bias value is displayed on the main screen while you adjust it as well
as on the relevant individual display.
The full range of operations is:
Rotate: Adjust the Attenuation / Bias
Click: Toggle the focus between the Attenuation and Bias
Click and hold Restore default parameters for that channel / band
Multi-click: Click two encoders near-simultaneously to create/delete channel
groups (see below)