Specifications

Cutting-Edge Power Technology 
Makes The Difference
Liebert NX UPS Systems Incorporate A 
Number Of Other Exceptional Features:
High overload rating handles 125% for 10 minutes, 
150% for one minute and a 1000% overload for 10 
milliseconds.
Digital controls provide the fastest possible  
power management to enhance reliability, accuracy and 
efficiency.
Front access models available for installation along 
a wall. Front and rear access models available for 
installation in a row.
Compact footprint requires less floor space, leaving you 
with more room for other equipment.
Load Bus Synchronization standard. 
Soft Switching technology increases efficiency  
by up to 2% and saves energy. 
Integrated ground fault detection allows for effective 
transformer-less design while saving space and lowering 
the unit weight. 
Parallel for redundancy or capacity. 
Active input rectifier is generator  
and utility friendly. 
Web card monitoring standard.
One year warranty. 
Softscale
™
 technology, paralleling capabilities and Eco-mode
™
 all 
contribute to lower initial, incremental and operating costs.
Liebert NX 40-200 kVA UPS Systems  
Softscale Technology  
Liebert NX 40-200 kVA UPS systems have Softscale technology 
that provides flexibility to increase UPS capacity by 20 or 40kVA 
without changes in your infrastructure. Allows paralleling of 
unlike-sized models for capacity or redundancy. Designed for 
optimized performance with the same high efficiency at 40% 
utilization as at 100% utilization.
Paralleling Capabilities 
Liebert NX 40-200 kVA systems allow you to parallel UPS 
modules for capacity and redundancy, eliminating the 
batteries as a single point of failure because each UPS has its 
own isolated battery. Liebert NX also features integrated dual 
bus synchronization as a standard feature. This provides the 
capability to synchronize the outputs of two independent UPS 
modules when they are configured as a redundant system 
feeding independent distribution paths.
Eco-Mode High Efficiency Configuration 
If selected, this operating mode switches the UPS to static 
bypass during normal operation, increasing efficiency to up to 
97% at full load. When power problems are detected the UPS 
automatically switches back to double conversion mode.
Liebert NX BDC   
The optional Liebert NX BDC provides flexibility in input and 
output voltage for a variety of applications. This cabinet is 
available in capacities to cover the Liebert NX UPS range of 
40-200kVA. The monitoring panel matches the UPS unit. Power 
and control cabling from this cabinet to the UPS is included, 
enhancing ease of installation and availability. For ease of 
installation and maintenance, the cabinet offers top or bottom 
cable entry and models are available in front and rear access, or 
front access only configurations.
Liebert NX Power Core 
40-80 kVA
Enterprise UPS
29
DISCONTINUED 
PRO DU C T