Owner’s Manual Using your Domestic Ducted Evaporative Air Conditioning with the Climate Control Celair Profile Series Operating, Setup & Maintenance www.celair.com.au Please keep this important manual in a safe place. It is the owner’s responsibility to ensure that regular maintenance is carried out on this Evaporative Air Conditioner. Failure to do so will void all guarantees beyond statutory and legal requirements.
PROFILE SERIES OWNER’S MANUAL Contents INTRODUCTION ............................................................................................................. 4 DUCTED EVAPORATIVE AIR CONDITIONER ...................................................................... 5 INTRODUCTION .................................................................................................................... 5 Exhaust ..................................................................................................
PROFILE SERIES OWNER’S MANUAL Contents Setting the dump delay ................................................................................................................. 15 Setting the Pre-cool. ..................................................................................................................... 16 Setting the Dump Interval Cycles..................................................................................................
PROFILE SERIES OWNER’S MANUAL Introduction INTRODUCTION CONGRATULATIONS ON YOUR CHOICE We are delighted you have chosen an air conditioning product from Climate Technologies to cool your home. It’s an air conditioner we’re very proud of. Designed and made in Australia by Climate Technologies, 100% Australian owned company, it contains the latest advances in Fresh Air Conditioning technology in a stylish, attractive cabinet.
PROFILE SERIES OWNER’S MANUAL Ducted Evaporative Air Conditioner DUCTED EVAPOR AT IVE AIR COND ITIONER INTRODUCTION The Ducted Evaporative Air Conditioner is engineered to meet the rigors of our harsh Australian environment. Operated and maintained in accordance with this manual, it will provide you with years of quiet, cool and environmentally friendly operation. Please take the time to read this manual.
PROFILE SERIES OWNER’S MANUAL Ducted Evaporative Air Conditioner Dialflo BLEED OFF All evaporative air conditioners need some water bleed-off to prevent build-up of mineral deposits in the system. The correct setting of the bleed rate will ultimately govern the life of the unit. With normal town water supply, in good water quality areas, bleed rate should be adjusted so that the discharge is not less than 10 litres per hour subject to unit size.
PROFILE SERIES OWNER’S MANUAL Controls Operation OPER ATIN G TH E CONTR OL S Your ducted evaporative air conditioner has been supplied with the 4-button Climate control. The Climate controller has two modes of operation, MANUAL or AUTOMATIC. In addition it has a TIMER, which will operate in either mode. Manual Operation Fan Only Pressing the FAN button once will turn on the green fanlight and will start the fan only. The variable speed dial will vary the speed of the fan.
PROFILE SERIES OWNER’S MANUAL Controls Operation Timer Function The timer function operates either in Automatic or Manual modes and is designed to switch the unit ON or OFF in a pre-set period (two, four or eight hours). Note: Once the time function has activated or deactivated the unit, it will remain in this mode until another selection has been made at the wall control. Timer ON • To switch the unit ON in a pre-set time, firstly select FAN, COOL, or AUTO. Adjust the dial to your selected position.
PROFILE SERIES OWNER’S MANUAL Unit Maintenance UNIT M AINT EN ANCE Warning: Before commencing any maintenance work on your unit, isolate the power at the supply (Fuse Box). Note: It is essential that your evaporative air conditioner be maintained in accordance with this manual. Failure to do so will affect the life of the product and reduce the level of efficiency. FILTER PADS Visually check CELDEK pads for damage or blockage.
PROFILE SERIES OWNER’S MANUAL Unit Maintenance WATER DISTRIBUTION Check the water distribution system for blockage. Check the delivery tube for kinks or holes. Check that the clamps are secure and in place.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning CONTROL SETUP & COMM ISSIONING Your evaporative air conditioner has been supplied with the Climate Low voltage control featuring basic control options and thermostat, timed delayed starting and stopping, and dump valve features. This low voltage controls are connected to the air conditioner control box via a 20-metre low voltage loom. NOTE: Do not run the low voltage loom in long parallel runs with 240V mains cables.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning CONTROL LOCATION Climate wall control: • Locate the wall switch on an internal wall of a conditioned room of the home, approximately 1.5M above the floor level, in an easily accessible location as agreed with the customer. • The controller must not be installed into areas where a ceiling register may blow cold air over the control, or installed near appliances that may generate heat. This will cause erratic thermostat operation.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning TEK 600 WIRING DIAGRAM TEK600 SERIES CONTROL Page 13
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning CLIMATE CONTROL – SETUP OPTIONS This controller has a number of options for the installer to set before commissioning the unit. Options OPERATION FUNCTION This mode controls the dump valve. (If fitted). DUMP DELAY PRE-COOL The dump delay is used to set the dump valve to dump 40 seconds after the pump is turned off or can be set to dump one hour after the pump has turned off.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning Parameter Settings Table The below table is a parameter chart for setting the unit. This chart is also printed on the back of the wall switch. Setting Installer Parameters.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning Setting the Pre-cool. (4 hour light on and Auto light flashing). 1. To disable the Pre-cool feature rotate the dial fully to the minimum position and the auto light will flash once every two seconds. 2. To activate the Pre-cool feature rotate the dial fully to the maximum position and the auto light will flash twice every two seconds. 3. Press the FAN button once to select the desired mode.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning Reviewing Programmed Settings. To review the settings entered into the Climate control, enter the parameter setting mode as explained from steps one to four on Page 15. Once entering the parameter setting mode DO NOT ROTATE THE ADJUSTABLE DIAL. Read the number of flashes from the AUTO light in with the two-hour light on. 1. Press the AUTO button once and the four-hour light will turn on, read the number of flashes from the AUTO light. 2.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning Setting the Thermostat Control Minimum / Maximum speed settings. 1. Start with the wall switch in the off mode. 2. Press and hold the auto and timer buttons for ten seconds then release, after releasing these two buttons press and release the timer button once. 3. The auto light will flash continuously and the four-hour light will flash once every two seconds, this indicates that the unit is ready for low speed adjustment.
PROFILE SERIES OWNER’S MANUAL Controls Setup & Commissioning COMMISSIONING CHECK LIST General All equipment ordered by the customer is installed. The unit is level and secure. The mains and control wiring are complete and the circuit breaker and GPO are turned ON. All Controller functions for the appliance operate. All electrical or water connections are to manufacturers specifications and the relevant electrical or plumbing standards and codes.
PROFILE SERIES OWNER’S MANUAL Warranty – Australia ONLY W ARRANT Y IMPORTANT: Please read this warranty information and complete the Dealer/Product information on the following page. KEEP this with your original purchase documents for any claim under warranty. Firstly refer to your owners manual to ensure you have followed the correct operating procedures of your product, and refer to the trouble shooting guide to assist solving any problems you may have. 1.
PROFILE SERIES OWNER’S MANUAL Warranty – Australia ONLY Exclusions to Warranty. • Consumable items subject to wear and tear such as filter pads drive belts and bearings are not covered by this warranty. • Components used as part of the installation such as grilles, filters, ducting, fittings, zone motors and consumer services pipe work are warranted from your place of purchase and not covered by this warranty.
PROFILE SERIES OWNER’S MANUAL Warranty – Australia ONLY PERIODS OF WARRANTY – YEARS BY PRODUCT AND APPLICATION: Ducted Evaporative Air Conditioning - Domestic Unit Components RESIDENTIAL Parts COMMERCIAL Labour Parts Labour Corrosion on Cabinet 25 3 2 2 Structural Guarantee 10 3 2 2 ** All other components 3 3 1 1 ** Filter pads are a consumable and are therefore not covered by this warranty 2 Year Extended Warranty Where a 2 year extended warranty has been sold / provided, a validati
PROFILE SERIES OWNER’S MANUAL Warranty – AUSTRALIA ONLY SER VIC E SERVICE CENTRES: Only qualified service personnel should conduct any service work carried out on your ducted air conditioning system. It is important that periodical service is carried out on your product to ensure your will receive the efficiency benefits the product provides.
Manufactured by Climate Technologies ABN 13 001 418 042 26 Nylex Avenue Salisbury, SA 5108 Australia www.celair.com.