Specifications

8.3 Modifying Sequences
Once a Sequence has been programmed, it can be modified,
allowing steps to be edited, inserted, or deleted.
8.3.1 Editing a step
To edit a step, proceed as follows:
1 Move to the “[STORE] [SEQUENCE]” menu.
Note The Sequence will automatically stop, indicated by the LED in the
Stop button illuminating.
2 To select the step number to edit, use the [>] and [<] soft buttons to
move the cursor to Step field, and the Master Select to increment or
decrement the value to the required setting; alternatively, press the
Step button to move through the steps until the required one is
reached.
Note As the step number changes, the settings for that step are output
on the console.
3 Press the Mod button. All the LTP channels associated with the
Sequence step are automatically selected, indicated by the LEDs in
their Select buttons illuminating.
4 To remove any unwanted LTP channels from the Sequence Step,
simply press the corresponding Select button; its’ LED is
extinguished. Similarly, to add any channels to the Sequence Step,
press the corresponding Select button; its’ LED is illuminated.
For channels operating in HTP mode, their levels are set by
rotating the corresponding Rotary Controls and are automatically
removed from the Sequence when their levels are zero (off), and
included when their levels are non-zero (on).
Navigator Operators Manual
60 EPD01003 Issue 3 (30/06/94)