User guide
73
EXAMPLE —Calling-up an Entity Screen using object
grouping...
To set the same parameters for Channels 1, 3 and 5 thru 30, press
the following buttons:
Button Command Line Display Result
chan
Chan
Entity type selected
1
chan 1
&
chan 1 +
channel 1 selected
3
chan 1 + 3
&
chan 1 + 3 +
channel 1 and 3 selected
5
chan 1 + 3 + 5
~
chan 1 + 3 + 5 -
channels 1, 3 and 5 selected
3
chan 1 + 3 + 5 - 3
0
chan 1 + 3 + 5 - 30
next
Channel Set- up Screen
appears for Channels 1, 3,
and 5 thru 30:
Channel: 1+3+5-30{Chan 1} Mode: Htp
Dimmer: 1 Total: 1/1 Patch @ 100
[View]
IMPORTANT NOTE
When defining an object group, the last item number is not actually
selected until followed by a separator (i.e. + or -) or until the Command
Line is accepted by the next , enter or @ buttons.
EXAMPLE —Using Keypad Control...
To set Channels 4 and 9 thru 25 to a level of 75%, press the
following buttons:
Button Command Line Display Result
chan
chan
Entity type selected
4
chan 4
&
chan 4 +
Channel 4 selected
9
chan 4 + 9
~
chan 4 + 9 -
Channels 4 and 9 selected
2
chan 4 + 9 - 2
5
chan 4 + 9 - 25
@ or
enter
Channels 4 and 9 thru 25 are
selected, and cursor moves
to the second Command
Line:
Celco Ventura Console V3.2 Program
Commands: Channel 4+9-25
@0 Space: 97.39%
[SETUP] [I/O]
You can now set the level by using the Digital Fader, Rotary Select Wheel,
the + and – buttons or by directly keying- in a value on the keypad:
7
@70
selected Channels at 70%
5
@75
selected Channels at 75%