User guide

82
Screen 2 – Pan/Tilt Overrides
Setup for Lamps
Lamp 1 Type: Mac 2000
Pan:Norm Tilt:Norm
Pan/Tilt:Norm
(Soft)Button Function
Exit
Go back to root menu
Next
Go to lamp entity screen 3
(1)
No function
(2)
No function
(3)
No function
Field name Value Description
Lamp
1 – 100 The chosen Lamp object number (or
grouping).
Type
Various Lamp type.
Pan
Norm
Inv
Use the ‘Inv’ setting to reverse the Pan
operation. Default is ‘Norm’.
Tilt
Norm
Inv
Use the ‘Inv’ setting to reverse the Tilt
operation. Default is ‘Norm’.
Pan/Tilt
Norm
Swap
Use the ‘Swap’ setting to swap the
Channels used for Pan & Tilt control.
Default is ‘Norm’.
Screen 3 – Autotracking Set-up
Tracking Setup 3
Lamp: 1 Mac 2000 |
Stage position: 1 2--1
[Set Pos] [Show Pos] [Adjust]
(Soft)Button Function
Exit
Go back to root menu
Next
Go to lamp entity screen 1
(1) Set Pos
To store the tracking position.
(2) Show Pos
To show the tracking position.
(3) Adjust
To adjust the tracking position.
Field name Value Description
Lamp
1 – 100 Lamp Number (defaults to the value
chosen on screen 1)
Stage position
1 – 3 Tracking position